Effect of Intracavitary ECG and P-wave Ratio on Neonatal PICC Localization

Objective: To investigate the relationship between the P-wave size of neonatal PICC intracavitary electrocardiogram (ECG)tip and the position of PICC catheter tipin superior vena cava and its clinical effect. Methods: A total of 184 patients with PIC-C catheterization were enrolled in the study. They were randomly divided into observation group and control group according to the random number table method, 92 cases in each group. The control group took the regular body surface and the chest X-ray positioning after operation, while the observation group was located by intracavitary EC-G P-wave ratio and chest X-ray. The disposable catheter success rate and time of catheterization were compared between the two groups, and the position of catheter tip corresponding to different Pwaves was analyzed. Results: The PICC disposable catheter success rate of the newborns in the observation group was 95. 65(88/92), which was significantly higher than that of the control group (81.52%, 75/92) (P<0.01). The catheterization time and the puncture sitebleeding volume in the observation group were significantly lower than the control group(P<0.01). In the observation group, the tip of the catheter of 1/2 -2/3 R wave was mainly recommended by the guideline, the 1/3-1/2 R wave was mainly 2/3 of the superior vena cava, and the 1/2~2/3 R wave was mainly recommended by the guideline or right atrium, the difference was statistically significant (P<0.05). Conclusions: The P-wave ratio of intracavitary ECG is helpful to locate the tip of neonatal PICC.

Authors

Institutions

Publication Details

Journal
Journal of Contemporary Medical Practice
Published
2025-04-29
DOI
https://doi.org/10.53469/jcmp.2025.07(04).26
Citations
1
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
1.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Intracavitary ECG and P-wave Ratio on Neonatal PICC Localization

Xiaomei Lu, Liang Fa-yu, Huaxiang Lu, Li Huang et al.
1 citations
Journal of Contemporary Medical Practice
Cardiac Arrhythmias and Treatments
1.39
article

Effect of Intracavitary ECG and P-wave Ratio on Neonatal PICC Localization

Xiaomei Lu, Liang Fa-yu, Huaxiang Lu, Li Huang, Wei Shan Li, Y Ling
article en
1 citations

Abstract

Objective: To investigate the relationship between the P-wave size of neonatal PICC intracavitary electrocardiogram (ECG)tip and the position of PICC catheter tipin superior vena cava and its clinical effect. Methods: A total of 184 patients with PIC-C catheterization were enrolled in the study. They were randomly divided into observation group and control group according to the random number table method, 92 cases in each group. The control group took the regular body surface and the chest X-ray positioning after operation, while the observation group was located by intracavitary EC-G P-wave ratio and chest X-ray. The disposable catheter success rate and time of catheterization were compared between the two groups, and the position of catheter tip corresponding to different Pwaves was analyzed. Results: The PICC disposable catheter success rate of the newborns in the observation group was 95. 65(88/92), which was significantly higher than that of the control group (81.52%, 75/92) (P<0.01). The catheterization time and the puncture sitebleeding volume in the observation group were significantly lower than the control group(P<0.01). In the observation group, the tip of the catheter of 1/2 -2/3 R wave was mainly recommended by the guideline, the 1/3-1/2 R wave was mainly 2/3 of the superior vena cava, and the 1/2~2/3 R wave was mainly recommended by the guideline or right atrium, the difference was statistically significant (P<0.05). Conclusions: The P-wave ratio of intracavitary ECG is helpful to locate the tip of neonatal PICC.

Journal of Contemporary Medical PracticeVol. 7(4)
Affiliated Hospital of Youjiang Medical University for Nationalities (CN)
Openalex Percentile: Top 20%
Cardiac Arrhythmias and Treatments
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.