Enhancing full-field TXM with low emittance synchrotron sources: Mono-capillary condenser shaker optimization

Synchrotron radiation based full-field transmission hard x-ray microscope (TXM) achieves spatial resolutions ranging from a few to tens of nanometers. The field of view (FOV) and resolution are contingent upon the illumination characteristics of the condenser, the zone plate, and the detector. With the technological advancements in synchrotron radiation accelerators, there has been a progressive reduction in the electron beam emittance. The focused spot by the condenser in TXM systems utilizing a mono-capillary condenser has also become smaller, consequently narrowing the TXM's FOV. Additionally, due to slope errors of the mono-capillary condenser, the focused spot is non-uniform, leading to a non-uniform FOV in TXM. To address these issues, a condenser shaker has been implemented. This study presents theoretical analysis, simulations, and experimental data, illustrating the impacts of different amplitudes and frequencies of the condenser shaker on the focused spot, TXM's FOV, and imaging quality. The results indicate that the FOV of TXM increases nearly double when the condenser shaker is optimally applied, compared to its absence. These enhancements signify that the optimization of mono-capillary condenser shaking in the TXM system can expand the FOV and significantly enhance the overall imaging quality. Through this optimization, three-dimensional nano-imaging of a battery particle with a 28 μm diameter and 96 nm micro-structures was successfully achieved.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2025-05-01
DOI
https://doi.org/10.1063/5.0256187
Citations
2
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
3.77

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing full-field TXM with low emittance synchrotron sources: Mono-capillary condenser shaker optimization

Naxi Tian, Yichi Zhang, Jun Wang, Ling Zhang et al.
2 citations
Review of Scientific Instruments
Advanced X-ray Imaging Techniques
3.77
article

Enhancing full-field TXM with low emittance synchrotron sources: Mono-capillary condenser shaker optimization

Naxi Tian, Yichi Zhang, Jun Wang, Ling Zhang, Fen Tao, Guohao Du, Biao Deng
article en
2 citations

Abstract

Synchrotron radiation based full-field transmission hard x-ray microscope (TXM) achieves spatial resolutions ranging from a few to tens of nanometers. The field of view (FOV) and resolution are contingent upon the illumination characteristics of the condenser, the zone plate, and the detector. With the technological advancements in synchrotron radiation accelerators, there has been a progressive reduction in the electron beam emittance. The focused spot by the condenser in TXM systems utilizing a mono-capillary condenser has also become smaller, consequently narrowing the TXM's FOV. Additionally, due to slope errors of the mono-capillary condenser, the focused spot is non-uniform, leading to a non-uniform FOV in TXM. To address these issues, a condenser shaker has been implemented. This study presents theoretical analysis, simulations, and experimental data, illustrating the impacts of different amplitudes and frequencies of the condenser shaker on the focused spot, TXM's FOV, and imaging quality. The results indicate that the FOV of TXM increases nearly double when the condenser shaker is optimally applied, compared to its absence. These enhancements signify that the optimization of mono-capillary condenser shaking in the TXM system can expand the FOV and significantly enhance the overall imaging quality. Through this optimization, three-dimensional nano-imaging of a battery particle with a 28 μm diameter and 96 nm micro-structures was successfully achieved.

Review of Scientific InstrumentsVol. 96(5)
Chinese Academy of Sciences (CN), Shanghai Advanced Research Institute (CN), Shanghai Institute of Applied Physics (CN), University of Chinese Academy of Sciences (CN)
National Natural Science Foundation of China-Yunnan Joint Fund, National Key Research and Development Program of China
Affordable and clean energy
Openalex Percentile: Top 8%
Advanced X-ray Imaging Techniques
3.77
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.