Patient Comfort, Acceptance, and Tolerability of Virtual Reality (VR) Headsets with Real-Time Eye Tracking for Remote Visual Field Testing

<b>Objectives</b>: Visual field (VF) testing is key to assessing functional loss in glaucoma. Despite its clinical value, traditional VF testing has a number of limitations, including its dependency on medical equipment and posturing requirements. The present study examines the acceptance, tolerability, and comfort of home-based VF testing using a virtual reality (VR) headset. <b>Method</b>: Healthy subjects were prospectively enrolled to undergo VF examination in a non-clinical setting using a commercially available stereoscopic VR headset and SORS (sequentially optimized reconstruction strategy) on the VisionOne platform. Subjects were supervised and wore their own spectacles within the headset. After the VR VF test, they were asked about their comfort, side effects, and readiness to repeat the examination at home. <b>Results</b>: Of the 12 subjects enrolled, 7 were female (58.3%) and 5 were male (41.7%). Mean age was 45 years (range: 30-68). While none of the subjects suffered from glaucoma, their medical histories included severe arthritis, refractive surgery, high myopia, amblyopia, and esotropia. The mean self-reported comfort score was 8.75 out of 10 (range: 8-10), with some subjects taking the test in the dorsal decubitus position. Eleven subjects (91.7%) considered the device to be easy to use, and 100% responded that they would be willing to repeat the test at home, of which 41.7% stated they would prefer to be supervised by a clinician. Overall, three subjects reported mild side effects, namely light asthenopia, epiphora, and periocular flushing. All side effects were mild and self-limited. The mean perceived duration of the test (187 s) correlated strongly with the mean actual duration (166 s; Pearson correlation coefficient r = 0.76, <i>p</i>-value = 0.007). In all, 58.3% of perceived durations were shorter than the actual test durations. Mean false negative and false positive responses were 3.75% and 4.7%, respectively. Central fixation recorded by real-time eye tracking was maintained on average 73.23% of the time and showed a strong correlation with false negative responses (r = 0.75; <i>p</i> = 0.026). <b>Conclusions</b>: While the present study did not examine the test algorithm itself, it suggests that home-based VF testing using a VR headset is well tolerated and accepted, with high levels of self-reported comfort and only mild side effects. While all subjects welcomed the opportunity to perform clinical tests from home, over a third expressed a preference for supervision. Real-time eye tracking correlated well with traditional reliability markers, suggesting potential clinical value.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-05-06
DOI
https://doi.org/10.3390/jcm14093219
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Patient Comfort, Acceptance, and Tolerability of Virtual Reality (VR) Headsets with Real-Time Eye Tracking for Remote Visual Field Testing

Athena Lallouette, Kevin Gillmann
Journal of Clinical Medicine
Glaucoma and retinal disorders
article

Patient Comfort, Acceptance, and Tolerability of Virtual Reality (VR) Headsets with Real-Time Eye Tracking for Remote Visual Field Testing

Athena Lallouette, Kevin Gillmann
article en

Abstract

<b>Objectives</b>: Visual field (VF) testing is key to assessing functional loss in glaucoma. Despite its clinical value, traditional VF testing has a number of limitations, including its dependency on medical equipment and posturing requirements. The present study examines the acceptance, tolerability, and comfort of home-based VF testing using a virtual reality (VR) headset. <b>Method</b>: Healthy subjects were prospectively enrolled to undergo VF examination in a non-clinical setting using a commercially available stereoscopic VR headset and SORS (sequentially optimized reconstruction strategy) on the VisionOne platform. Subjects were supervised and wore their own spectacles within the headset. After the VR VF test, they were asked about their comfort, side effects, and readiness to repeat the examination at home. <b>Results</b>: Of the 12 subjects enrolled, 7 were female (58.3%) and 5 were male (41.7%). Mean age was 45 years (range: 30-68). While none of the subjects suffered from glaucoma, their medical histories included severe arthritis, refractive surgery, high myopia, amblyopia, and esotropia. The mean self-reported comfort score was 8.75 out of 10 (range: 8-10), with some subjects taking the test in the dorsal decubitus position. Eleven subjects (91.7%) considered the device to be easy to use, and 100% responded that they would be willing to repeat the test at home, of which 41.7% stated they would prefer to be supervised by a clinician. Overall, three subjects reported mild side effects, namely light asthenopia, epiphora, and periocular flushing. All side effects were mild and self-limited. The mean perceived duration of the test (187 s) correlated strongly with the mean actual duration (166 s; Pearson correlation coefficient r = 0.76, <i>p</i>-value = 0.007). In all, 58.3% of perceived durations were shorter than the actual test durations. Mean false negative and false positive responses were 3.75% and 4.7%, respectively. Central fixation recorded by real-time eye tracking was maintained on average 73.23% of the time and showed a strong correlation with false negative responses (r = 0.75; <i>p</i> = 0.026). <b>Conclusions</b>: While the present study did not examine the test algorithm itself, it suggests that home-based VF testing using a VR headset is well tolerated and accepted, with high levels of self-reported comfort and only mild side effects. While all subjects welcomed the opportunity to perform clinical tests from home, over a third expressed a preference for supervision. Real-time eye tracking correlated well with traditional reliability markers, suggesting potential clinical value.

Journal of Clinical MedicineVol. 14(9)
Queen Mary University of London (GB)
Openalex Percentile: Top 84%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.