Cavitation activity induced by spring-loaded core needle biopsy devices

Core needle biopsy is a common medical procedure to obtain tissue samples with tissue architecture for pathological assessment. One prevalent method involves the use of spring-loaded core needle biopsy devices, or "biopsy guns". Despite their intense motion dynamics when shot through tissue, possible cavitation activity has received limited attention. Cavitation bubbles imploding in biological environments are known for their mechanical effects on cells and tissue. In this study, visual and acoustic monitoring was applied to characterize and quantify cavitation phenomena around longitudinally or flexurally oscillating core needle biopsy needles, when immersed in deionized water or embedded in agarose-based tissue mimicking phantom. In water, we observed that cavitation was most prominent with side cut needle, but bubble activity was also present with front cut needle. In agarose, the intensity of the cavitation was found to decrease with increasing agarose concentration. Cavitation was still observed at 0.3% w/v agarose gel, but at 1.0% w/v gel, cavitation activity was essentially eliminated. Acoustic emission was observed with both needle types from audible to ultrasound ranges. The study suggests that cavitation as a physical mechanism can occur in operation of spring-loaded core needle biopsy devices in water and tissue-mimicking hydrogels and should be considered as an opportunity for the development of new in vivo applications related to the echogenicity of the cavitation bubbles in ultrasound imaging as well as considered as a physical mechanism for safety studies.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-05-06
DOI
https://doi.org/10.1038/s41598-025-97497-z
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cavitation activity induced by spring-loaded core needle biopsy devices

Maxime Fauconnier, Heikki J. Nieminen, Jussi Kiviluoto
Scientific Reports
Ultrasound and Hyperthermia Applications
article

Cavitation activity induced by spring-loaded core needle biopsy devices

Maxime Fauconnier, Heikki J. Nieminen, Jussi Kiviluoto
article en

Abstract

Core needle biopsy is a common medical procedure to obtain tissue samples with tissue architecture for pathological assessment. One prevalent method involves the use of spring-loaded core needle biopsy devices, or "biopsy guns". Despite their intense motion dynamics when shot through tissue, possible cavitation activity has received limited attention. Cavitation bubbles imploding in biological environments are known for their mechanical effects on cells and tissue. In this study, visual and acoustic monitoring was applied to characterize and quantify cavitation phenomena around longitudinally or flexurally oscillating core needle biopsy needles, when immersed in deionized water or embedded in agarose-based tissue mimicking phantom. In water, we observed that cavitation was most prominent with side cut needle, but bubble activity was also present with front cut needle. In agarose, the intensity of the cavitation was found to decrease with increasing agarose concentration. Cavitation was still observed at 0.3% w/v agarose gel, but at 1.0% w/v gel, cavitation activity was essentially eliminated. Acoustic emission was observed with both needle types from audible to ultrasound ranges. The study suggests that cavitation as a physical mechanism can occur in operation of spring-loaded core needle biopsy devices in water and tissue-mimicking hydrogels and should be considered as an opportunity for the development of new in vivo applications related to the echogenicity of the cavitation bubbles in ultrasound imaging as well as considered as a physical mechanism for safety studies.

Scientific ReportsVol. 15(1)
Aalto University (FI)
Academy of Finland, Suomen Kulttuurirahasto
Clean water and sanitation
Openalex Percentile: Top 91%
Ultrasound and Hyperthermia Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.