Decoding the Rotation Effect: A Retrospective Analysis of Lesion Orientation and Its Impact on Wavelet-Based Radiomics Feature Extraction and Lung Cancer Classification

Wavelet decomposition (WD), widely used in radiomics, redistributes information among derived wavelet components when the input is rotated. This redistribution may alter predictions for the same lesion when scanned at different angles. Despite its potential significance, this vulnerability has frequently been overlooked in radiomic studies while its impact remains poorly understood. Therefore, this study aims to investigate how variations in lesion orientation affect both WD and non-WD radiomic feature values, and subsequently, model performance. We analyzed CT radiomics of primary non-small-cell lung cancer (NSCLC). Prior to feature extraction, we introduced random rotations ranging from 5° to 80° to the tumors. Their effects were quantified by evaluating the percentage difference ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mo>%</mml:mo> <mml:mi>Δ</mml:mi></mml:mrow> </mml:math> ) between the rotated and unrotated feature values, and validated using Spearman's rank test. Additionally, radiomics models were trained to discriminate between three histological subtypes of NSCLC using the original features, and then tested on rotated inputs. The correlation between the model accuracies and the degree of rotation was again evaluated using Spearman's rank test. Four-hundred nineteen NSCLC patients (mean age: 68.1 ± 10.1, 289 men) were evaluated. Significant correlations between feature values and rotations (Spearman's correlation [CC] magnitude ≥ 0.1, p < .05) were found in 23.7% (176/744) of the WD and 0.5% (5/930) of the non-WD texture features. Significant association between performance and rotation was observed in WD-based models built to discriminate between NSCLC histological subtypes (CC = - 0.44, p < .001) but not in non-WD-based models (CC = 0.03, p = 0.07). Input lesion orientation affects radiomic feature values and model reproducibility. WD features exhibited significantly greater instability to orientation variations compared to non-WD features.

Authors

Institutions

Publication Details

Journal
Journal of Imaging Informatics in Medicine
Published
2025-05-06
DOI
https://doi.org/10.1007/s10278-025-01520-8
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Decoding the Rotation Effect: A Retrospective Analysis of Lesion Orientation and Its Impact on Wavelet-Based Radiomics Feature Extraction and Lung Cancer Classification

Lun M. Wong, Howard Leung, Qi Yong H. Ai, Ann D. King et al.
1 links
Journal of Imaging Informatics in Medicine
Radiomics and Machine Learning in Medical Imaging
article

Decoding the Rotation Effect: A Retrospective Analysis of Lesion Orientation and Its Impact on Wavelet-Based Radiomics Feature Extraction and Lung Cancer Classification

Lun M. Wong, Howard Leung, Qi Yong H. Ai, Ann D. King, Yuet-Ting Chan, Kuo Feng Hung, Tiffany Y. So
article en

Abstract

Wavelet decomposition (WD), widely used in radiomics, redistributes information among derived wavelet components when the input is rotated. This redistribution may alter predictions for the same lesion when scanned at different angles. Despite its potential significance, this vulnerability has frequently been overlooked in radiomic studies while its impact remains poorly understood. Therefore, this study aims to investigate how variations in lesion orientation affect both WD and non-WD radiomic feature values, and subsequently, model performance. We analyzed CT radiomics of primary non-small-cell lung cancer (NSCLC). Prior to feature extraction, we introduced random rotations ranging from 5° to 80° to the tumors. Their effects were quantified by evaluating the percentage difference ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mo>%</mml:mo> <mml:mi>Δ</mml:mi></mml:mrow> </mml:math> ) between the rotated and unrotated feature values, and validated using Spearman's rank test. Additionally, radiomics models were trained to discriminate between three histological subtypes of NSCLC using the original features, and then tested on rotated inputs. The correlation between the model accuracies and the degree of rotation was again evaluated using Spearman's rank test. Four-hundred nineteen NSCLC patients (mean age: 68.1 ± 10.1, 289 men) were evaluated. Significant correlations between feature values and rotations (Spearman's correlation [CC] magnitude ≥ 0.1, p < .05) were found in 23.7% (176/744) of the WD and 0.5% (5/930) of the non-WD texture features. Significant association between performance and rotation was observed in WD-based models built to discriminate between NSCLC histological subtypes (CC = - 0.44, p < .001) but not in non-WD-based models (CC = 0.03, p = 0.07). Input lesion orientation affects radiomic feature values and model reproducibility. WD features exhibited significantly greater instability to orientation variations compared to non-WD features.

Journal of Imaging Informatics in MedicineVol. 39(1)
Hospital Authority (HK), Chinese University of Hong Kong (HK), Community Care (US), Prince of Wales Hospital (CN), University of Hong Kong (HK)
Reduced inequalities
Openalex Percentile: Top 85%
Radiomics and Machine Learning in Medical Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.