Design and Accuracy Evaluation of a Depth Gauge-Referencing Guide System for Measuring Articular Cartilage Thickness on the Distal Femoral Condyles During Unrestricted Kinematically Aligned Total Knee Arthroplasty

Abstract Regardless of pre-operative deformity, unrestricted kinematically aligned (unKA) total knee arthroplasty (TKA) seeks to restore the native femoral joint lines which requires that the thickness of articular cartilage be determined in vivo at the location on a resection where thickness is greatest. Available methods for making this measurement are complex, costly, and offer challenges in pinpointing the location of maximum resection thickness. The purposes were to describe a new mechanical depth gauge-referencing guide system for making this measurement on the distal femoral resections and quantify accuracy of the measurement during unKA TKA. A new mechanical depth gauge was designed which offered a blunt tipped probe to avoid penetrating the subcondylar bone and a calibrated plunger. To ensure that cartilage thickness was measured where the resection is thickest, a custom transparent distal femoral referencing guide was designed which correctly located the depth gauge. To determine accuracy, the system was used to measure articular cartilage thickness on 100 resections taken from 93 patients undergoing unKA TKA. To serve as a gold standard, cartilage thickness was measured following resection using a calibrated photograph. Both systematic (bias) and random (precision) errors were computed. The depth gauge-referencing guide system provided thickness measurements which were unbiased and with precision less than the 0.5 mm resolution of the calibrated plunger, which is the resolution needed for restoration of native joint lines within an acceptable tolerance. Accordingly, the new mechanical depth gauge-referencing guide system provides surgeons with a proven tool for intra-operative measurement of cartilage thickness.

Authors

Institutions

Publication Details

Journal
Journal of Medical Devices
Published
2025-05-06
DOI
https://doi.org/10.1115/1.4068613
Citations
3
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
6.02
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Accuracy Evaluation of a Depth Gauge-Referencing Guide System for Measuring Articular Cartilage Thickness on the Distal Femoral Condyles During Unrestricted Kinematically Aligned Total Knee Arthroplasty

Anand Dhaliwal, Alexander Johannes Nedopil, Maury L. Hull, Stephen Miller Howell
3 citations
Journal of Medical Devices
Total Knee Arthroplasty Outcomes
6.02
article

Design and Accuracy Evaluation of a Depth Gauge-Referencing Guide System for Measuring Articular Cartilage Thickness on the Distal Femoral Condyles During Unrestricted Kinematically Aligned Total Knee Arthroplasty

Anand Dhaliwal, Alexander Johannes Nedopil, Maury L. Hull, Stephen Miller Howell
article en
3 citations

Abstract

Abstract Regardless of pre-operative deformity, unrestricted kinematically aligned (unKA) total knee arthroplasty (TKA) seeks to restore the native femoral joint lines which requires that the thickness of articular cartilage be determined in vivo at the location on a resection where thickness is greatest. Available methods for making this measurement are complex, costly, and offer challenges in pinpointing the location of maximum resection thickness. The purposes were to describe a new mechanical depth gauge-referencing guide system for making this measurement on the distal femoral resections and quantify accuracy of the measurement during unKA TKA. A new mechanical depth gauge was designed which offered a blunt tipped probe to avoid penetrating the subcondylar bone and a calibrated plunger. To ensure that cartilage thickness was measured where the resection is thickest, a custom transparent distal femoral referencing guide was designed which correctly located the depth gauge. To determine accuracy, the system was used to measure articular cartilage thickness on 100 resections taken from 93 patients undergoing unKA TKA. To serve as a gold standard, cartilage thickness was measured following resection using a calibrated photograph. Both systematic (bias) and random (precision) errors were computed. The depth gauge-referencing guide system provided thickness measurements which were unbiased and with precision less than the 0.5 mm resolution of the calibrated plunger, which is the resolution needed for restoration of native joint lines within an acceptable tolerance. Accordingly, the new mechanical depth gauge-referencing guide system provides surgeons with a proven tool for intra-operative measurement of cartilage thickness.

Journal of Medical DevicesVol. 19(3)
University of Würzburg (DE), Klinik König-Ludwig Haus (DE), Valley Medical Center (US), California Northstate University (US), University of California Davis Medical Center (US), University of California, Davis (US)
Openalex Percentile: Top 4%
Total Knee Arthroplasty Outcomes
6.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.