Operation at Reduced Atmospheric Pressure and Concept of Reliability Redundancy for Optimized Design of Insulation Systems

Electrified transportation is calling for insulation design criteria that is adequate to provide elevated levels of power density, power dynamics and reliability. Increasing voltage levels are expected to cause accelerated intrinsic and extrinsic aging effects which will not be easily predictable at the design stage due to a lack of suitable modeling. Designing reliable insulation systems would require finding solutions able to control accelerated aging due to an unpredictable increase of intrinsic stresses and the onset of extrinsic stresses as partial discharges. This paper proposes the concept of reliability redundancy for the insulation design of aerospace electrical asset components, which is also validated at lower-than-standard atmospheric pressure. The principle is that extrinsic-aging-free design might be achieved upon determining the aging stress or abnormal service stresses distribution and being sure that aging will not generate conditions that can incept extrinsic aging (partial discharges) during operation life. However, such information is never, in practice, fully available to insulation system designers. Hence, especially in critical applications such as electrified aircraft, aerospace, and combat ships a further level of reliability should be added to a partial-discharge-free design, which can consist of the use of corona-resistant materials and/or of life models able to consider the accelerated aging effect of partial discharges (or any other type of extrinsic-accelerated aging factor). Innovative life modeling considering both extrinsic and intrinsic aging stresses, insulating material testing to estimate model parameters, and a metric for quantifying the extent of corona (or partial discharge) resistance can lead to establishing feasibility and limit conditions for optimized or fully reliability-redundant design. It is shown in the paper that if an extrinsic-aging-free design is not feasible, and it is therefore replaced by a redundant design, a further level of reliability redundancy can be provided by effective condition monitoring plans.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-05-06
DOI
https://doi.org/10.3390/en18092371
Citations
1
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.52

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Operation at Reduced Atmospheric Pressure and Concept of Reliability Redundancy for Optimized Design of Insulation Systems

Myneni Sukesh Babu, G Montanari
1 citations
Energies
High voltage insulation and dielectric phenomena
0.52
article

Operation at Reduced Atmospheric Pressure and Concept of Reliability Redundancy for Optimized Design of Insulation Systems

Myneni Sukesh Babu, G Montanari
article en
1 citations

Abstract

Electrified transportation is calling for insulation design criteria that is adequate to provide elevated levels of power density, power dynamics and reliability. Increasing voltage levels are expected to cause accelerated intrinsic and extrinsic aging effects which will not be easily predictable at the design stage due to a lack of suitable modeling. Designing reliable insulation systems would require finding solutions able to control accelerated aging due to an unpredictable increase of intrinsic stresses and the onset of extrinsic stresses as partial discharges. This paper proposes the concept of reliability redundancy for the insulation design of aerospace electrical asset components, which is also validated at lower-than-standard atmospheric pressure. The principle is that extrinsic-aging-free design might be achieved upon determining the aging stress or abnormal service stresses distribution and being sure that aging will not generate conditions that can incept extrinsic aging (partial discharges) during operation life. However, such information is never, in practice, fully available to insulation system designers. Hence, especially in critical applications such as electrified aircraft, aerospace, and combat ships a further level of reliability should be added to a partial-discharge-free design, which can consist of the use of corona-resistant materials and/or of life models able to consider the accelerated aging effect of partial discharges (or any other type of extrinsic-accelerated aging factor). Innovative life modeling considering both extrinsic and intrinsic aging stresses, insulating material testing to estimate model parameters, and a metric for quantifying the extent of corona (or partial discharge) resistance can lead to establishing feasibility and limit conditions for optimized or fully reliability-redundant design. It is shown in the paper that if an extrinsic-aging-free design is not feasible, and it is therefore replaced by a redundant design, a further level of reliability redundancy can be provided by effective condition monitoring plans.

EnergiesVol. 18(9)
Florida State University (US)
U.S. Department of Defense, U.S. Department of Energy, Office of Naval Research
Openalex Percentile: Top 39%
High voltage insulation and dielectric phenomena
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.