Effect of thermocouple design and engine exhaust pulsations on mean gas temperature accuracy

Accurate measurement and modeling of mean exhaust gas temperature (EGT) in internal combustion engines (ICEs) is paramount to improve its emission and efficiency while maintaining component durability. Sheathed thermocouples provide a robust and cost-effective EGT measurement to the detriment of accuracy due to the junction’s heat balance. Literature indicates that exposing and reducing the thermocouple junction diameter improves the mean measured EGT accuracy. However, such designs can affect its interaction with the pipe wall, the conventional heat sink for sheathed thermocouples. Furthermore, characteristics of the pulsating exhaust gas flow govern junction heat convection and heat conduction linked to the exposed wire length-to-diameter (l/d) ratio. Therefore, the complex interaction between thermocouple design attributes and the pulsating exhaust flow requires isolating the effects to derive the measurement accuracy benefits from exposed junction thermocouples. This study utilizes Type-K thermocouples in sheathed (6 mm) and multiwire exposed junction (51- 254 μ m ) constructions downstream of a single-pipe exhaust of a heavy-duty diesel engine. Isolated engine speed and load sweeps provided distinct pulsating exhaust flow conditions measured using a Pitot tube for mass flux and the exposed junction heating rate to indicate the true EGT. The study highlights fundamental differences in the junction-to-pipe wall thermal interaction between sheathed and exposed thermocouples, motivating the need for distinct heat sinks and error correction before comparing measurements. Moreover, the nature of the pulsating exhaust flow conditionally enhances or undermines gains in mean EGT accuracy. • Wall thermal interaction is distinct between sheathed and exposed junctions. • A single-pipe exhaust setup enables improved isolation of on-engine effects. • Heat convection was determined using the junction heating rate and a Pitot tube. • Mean exhaust gas temperature accuracy improves with junction diameter reduction. • Pulsating exhaust characteristics amplify or mask measurement accuracy improvements.

Authors

Institutions

Publication Details

Journal
Applied Thermal Engineering
Published
2025-05-06
DOI
https://doi.org/10.1016/j.applthermaleng.2025.126600
Primary Topic
Advanced Sensor Technologies Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of thermocouple design and engine exhaust pulsations on mean gas temperature accuracy

Andreas Cronhjort, Ulf Olofsson, Varun Venkataraman
Applied Thermal Engineering
Advanced Sensor Technologies Research
article

Effect of thermocouple design and engine exhaust pulsations on mean gas temperature accuracy

Andreas Cronhjort, Ulf Olofsson, Varun Venkataraman
article en

Abstract

Accurate measurement and modeling of mean exhaust gas temperature (EGT) in internal combustion engines (ICEs) is paramount to improve its emission and efficiency while maintaining component durability. Sheathed thermocouples provide a robust and cost-effective EGT measurement to the detriment of accuracy due to the junction’s heat balance. Literature indicates that exposing and reducing the thermocouple junction diameter improves the mean measured EGT accuracy. However, such designs can affect its interaction with the pipe wall, the conventional heat sink for sheathed thermocouples. Furthermore, characteristics of the pulsating exhaust gas flow govern junction heat convection and heat conduction linked to the exposed wire length-to-diameter (l/d) ratio. Therefore, the complex interaction between thermocouple design attributes and the pulsating exhaust flow requires isolating the effects to derive the measurement accuracy benefits from exposed junction thermocouples. This study utilizes Type-K thermocouples in sheathed (6 mm) and multiwire exposed junction (51- 254 μ m ) constructions downstream of a single-pipe exhaust of a heavy-duty diesel engine. Isolated engine speed and load sweeps provided distinct pulsating exhaust flow conditions measured using a Pitot tube for mass flux and the exposed junction heating rate to indicate the true EGT. The study highlights fundamental differences in the junction-to-pipe wall thermal interaction between sheathed and exposed thermocouples, motivating the need for distinct heat sinks and error correction before comparing measurements. Moreover, the nature of the pulsating exhaust flow conditionally enhances or undermines gains in mean EGT accuracy. • Wall thermal interaction is distinct between sheathed and exposed junctions. • A single-pipe exhaust setup enables improved isolation of on-engine effects. • Heat convection was determined using the junction heating rate and a Pitot tube. • Mean exhaust gas temperature accuracy improves with junction diameter reduction. • Pulsating exhaust characteristics amplify or mask measurement accuracy improvements.

Applied Thermal EngineeringVol. 274
KTH Royal Institute of Technology (SE)
Affordable and clean energy
Openalex Percentile: Top 91%
Advanced Sensor Technologies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.