A new indwelling urethral catheter (amSafeX) to verify the position of its balloon within the bladder during inflation

: Inserting a Foley catheter for urethral catheterization can lead to numerous iatrogenic injuries in patients, as it is difficult to ensure that the balloon is in the bladder during inflation. This video demonstrates the safety and effectiveness of a new design of indwelling urethral catheter (amSafeX) that confirms the presence of the balloon in the bladder during inflation. One hundred male patients who required a catheter for various reasons and 25 female postoperative patients were included in a prospective non-randomized interventional study. They were catheterized using the amSafeX catheter by a nurse or trainee doctor. The catheter features two draining eyes, with an additional eye proximal to the balloon and the usual distal eye blocked with an internal obturator attached to the string coming out of the drainage port. Standard instructions were given to follow the iSIP protocol of urethral catheterization. Data were collected and analyzed for the safety and efficacy of catheterization. From Jan 2022 to Oct 2022, none of the 125 patients had any adverse events during catheterization, and the obturator could be removed easily in all procedures. There were no incidents of peri-catheter leakage or urethral injury recorded during catheterization. The median duration of catheterization was 5 (3-12) days. : The innovative design of amSafeX indwelling urethral catheter ensured that the bulb was always present in the bladder during inflation. This may eliminate the risk of urethral injury.

Authors

Institutions

Publication Details

Journal
Urology Video Journal
Published
2025-05-06
DOI
https://doi.org/10.1016/j.urolvj.2025.100343
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A new indwelling urethral catheter (amSafeX) to verify the position of its balloon within the bladder during inflation

S. K. Singh, Shrey Jain, Rajiv Yadav, Anil Mandhani et al.
Urology Video Journal
Central Venous Catheters and Hemodialysis
article

A new indwelling urethral catheter (amSafeX) to verify the position of its balloon within the bladder during inflation

S. K. Singh, Shrey Jain, Rajiv Yadav, Anil Mandhani, JanardhanYC Reddy
article en

Abstract

: Inserting a Foley catheter for urethral catheterization can lead to numerous iatrogenic injuries in patients, as it is difficult to ensure that the balloon is in the bladder during inflation. This video demonstrates the safety and effectiveness of a new design of indwelling urethral catheter (amSafeX) that confirms the presence of the balloon in the bladder during inflation. One hundred male patients who required a catheter for various reasons and 25 female postoperative patients were included in a prospective non-randomized interventional study. They were catheterized using the amSafeX catheter by a nurse or trainee doctor. The catheter features two draining eyes, with an additional eye proximal to the balloon and the usual distal eye blocked with an internal obturator attached to the string coming out of the drainage port. Standard instructions were given to follow the iSIP protocol of urethral catheterization. Data were collected and analyzed for the safety and efficacy of catheterization. From Jan 2022 to Oct 2022, none of the 125 patients had any adverse events during catheterization, and the obturator could be removed easily in all procedures. There were no incidents of peri-catheter leakage or urethral injury recorded during catheterization. The median duration of catheterization was 5 (3-12) days. : The innovative design of amSafeX indwelling urethral catheter ensured that the bulb was always present in the bladder during inflation. This may eliminate the risk of urethral injury.

Urology Video JournalVol. 27
Shree Guru Gobind Singh Tricentenary University (IN), Fortis Memorial Research Institute (IN)
Openalex Percentile: Top 84%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A new indwelling urethral catheter (amSafeX) to verify the position of its balloon within the bladder during inflation — S. K. Singh, Shrey Jain, et al. · Urology Video Journal (2025) | TGRS Research Map | TGRS