High-resolution quantitative phase imaging via vortex beam speckle illumination

This study introduces a vortex beam speckle imaging system for quantitative phase imaging (QPI) with high lateral resolution. By introducing vortex beams for non-diffracting speckle field regulation, the speckle size can be significantly reduced from 116.32 μm to 11.07 μm. With these advantages, the proposed imaging system has shown 1.52 folds of lateral resolution improvement compared to a traditional coherent imaging system. Furthermore, the intensity signal-to-noise ratio of the imaging system has also been improved from 13.26 dB to 30.62 dB. Transport-of-intensity equation (TIE) phase retrieval algorithms were applied to standard quantitative phase targets, and red blood cell samples were used to demonstrate the system's precise phase retrieval capability, indicating its potential applications for label-free, non-invasive biomedical imaging.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2025-05-06
DOI
https://doi.org/10.1364/boe.560024
Citations
1
Primary Topic
Digital Holography and Microscopy
Type
article
Field-Weighted Citation Impact
1.25

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-resolution quantitative phase imaging via vortex beam speckle illumination

Y. S. Huang, Shengqiang Zhong, Xiantao Jiang, Yuhan Liu et al.
1 citations
Biomedical Optics Express
Digital Holography and Microscopy
1.25
article

High-resolution quantitative phase imaging via vortex beam speckle illumination

Y. S. Huang, Shengqiang Zhong, Xiantao Jiang, Yuhan Liu, Kai Zeng, C. Hou, Hongwei Zou, Fan Yang
article en
1 citations

Abstract

This study introduces a vortex beam speckle imaging system for quantitative phase imaging (QPI) with high lateral resolution. By introducing vortex beams for non-diffracting speckle field regulation, the speckle size can be significantly reduced from 116.32 μm to 11.07 μm. With these advantages, the proposed imaging system has shown 1.52 folds of lateral resolution improvement compared to a traditional coherent imaging system. Furthermore, the intensity signal-to-noise ratio of the imaging system has also been improved from 13.26 dB to 30.62 dB. Transport-of-intensity equation (TIE) phase retrieval algorithms were applied to standard quantitative phase targets, and red blood cell samples were used to demonstrate the system's precise phase retrieval capability, indicating its potential applications for label-free, non-invasive biomedical imaging.

Biomedical Optics ExpressVol. 16(6)
Sun Yat-sen University (CN), Jiangxi University of Technology (CN), Sir Syed University of Engineering and Technology (PK)
Natural Science Foundation of Guangdong Province, Shenzhen Fundamental Research Program, Fundamental Research Funds for the Central Universities
Affordable and clean energy
Openalex Percentile: Top 22%
Digital Holography and Microscopy
1.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.