Multipoint FBG Sensing System for Long-Range and Long-Term Structural Health Monitoring by Incoherent FMCW Optical Ranging System

Fiber Bragg gratings (FBGs) have been widely used for structural health monitoring (SHM) of large-scale infrastructures such as buildings and bridges. Although the wavelength division multiplexing (WDM) technique has been used to interrogate FBG sensors, the scalability is limited by the requirement of different Bragg wavelengths for each sensor. In this study, we developed the FBG-based sensing system utilizing the distance division multiplexing (DDM) technique realized by the incoherent frequency-modulated continuous-wave (I-FMCW) optical ranging system. Unlike the WDM technique, the proposed DDM technique allows multiple FBGs with identical Bragg wavelengths, which gives significant increase of the number of multiplexed sensors without requiring additional wavelength allocation. Moreover, because the I-FMCW optical ranging system does not rely on optical interference, it enables long-range interrogation over several kilometers, making it more robust and practical for SHM applications. We successfully demonstrated the FBG sensing system consisting of ten multiplexed FBGs in the 500 m-long fiber, achieving interrogation of 1 m ranging resolution and automatic multi-point temperature sensing in the range of 5°C to 75°C. Furthermore, we validated the long-term stability of the developed system over 48 hours with temperature measurement errors within a few degrees Celsius. Compared to the previous I-OFDR-based techniques, our work demonstrates practical SHM solution. These results highlight the potential of the I-FMCW-based DDM technique for scalable, long-range, and automated structural health monitoring.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-05-06
DOI
https://doi.org/10.1109/jsen.2025.3564040
Citations
3
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
2.19
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multipoint FBG Sensing System for Long-Range and Long-Term Structural Health Monitoring by Incoherent FMCW Optical Ranging System

Yuto Sugita, Ilda Abe, Jiaxun You, Koichi Iiyama et al.
3 citations
IEEE Sensors Journal
Advanced Fiber Optic Sensors
2.19
article

Multipoint FBG Sensing System for Long-Range and Long-Term Structural Health Monitoring by Incoherent FMCW Optical Ranging System

Yuto Sugita, Ilda Abe, Jiaxun You, Koichi Iiyama, Cheng Zhang, Meng Shan
article en
3 citations

Abstract

Fiber Bragg gratings (FBGs) have been widely used for structural health monitoring (SHM) of large-scale infrastructures such as buildings and bridges. Although the wavelength division multiplexing (WDM) technique has been used to interrogate FBG sensors, the scalability is limited by the requirement of different Bragg wavelengths for each sensor. In this study, we developed the FBG-based sensing system utilizing the distance division multiplexing (DDM) technique realized by the incoherent frequency-modulated continuous-wave (I-FMCW) optical ranging system. Unlike the WDM technique, the proposed DDM technique allows multiple FBGs with identical Bragg wavelengths, which gives significant increase of the number of multiplexed sensors without requiring additional wavelength allocation. Moreover, because the I-FMCW optical ranging system does not rely on optical interference, it enables long-range interrogation over several kilometers, making it more robust and practical for SHM applications. We successfully demonstrated the FBG sensing system consisting of ten multiplexed FBGs in the 500 m-long fiber, achieving interrogation of 1 m ranging resolution and automatic multi-point temperature sensing in the range of 5°C to 75°C. Furthermore, we validated the long-term stability of the developed system over 48 hours with temperature measurement errors within a few degrees Celsius. Compared to the previous I-OFDR-based techniques, our work demonstrates practical SHM solution. These results highlight the potential of the I-FMCW-based DDM technique for scalable, long-range, and automated structural health monitoring.

IEEE Sensors JournalVol. 25(12)
Kanazawa University (JP)
Openalex Percentile: Top 12%
Advanced Fiber Optic Sensors
2.19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Multipoint FBG Sensing System for Long-Range and Long-Term Structural Health Monitoring by Incoherent FMCW Optical Ranging System — Yuto Sugita, Ilda Abe, et al. · IEEE Sensors Journal (2025) | TGRS Research Map | TGRS