Determination of Cadmium and Zinc in Soil Samples Using Magnetic Field-Assisted Solution Cathode Glow Discharge

A magnetic field-assisted solution cathode glow discharge (MF-SCGD) was established and then applied for the detection of Cd and Zn in soil samples. In order to reveal the signal enhancement mechanism of the magnetic field, the influence of the magnetic field strength on plasma parameters, such as electron temperature and electron density, was investigated. The results showed that adding a 0.5 T magnetic field significantly reduces the red-hot degree of the Pt needle, decreases the volume of the plasma torch, extends the lifespan of the Pt needle, and widens the application range of voltage. The optimal operating parameters of MF-SCGD were identified as a 0.5 T magnetic field, 680 V discharge voltage, 3.2 mL/min solution flow rate, and pH 1.0 HNO3 as the supporting electrolyte. Under optimal conditions, the intensities of Cd and Zn signals increased by 1.7 and 1.8 times, respectively. The limits of detection were 9.1 μg/L for Cd and 12.0 μg/L for Zn. After adding a 0.5 T magnetic field, electron temperature slightly decreased while electron density increased. The plasma parameter β was found to be less than 1, indicating that signal intensity enhancement is due to magnetic confinement. The analysis results of Cd and Zn in certified reference materials and two soil samples are consistent with the certified standard and verified values obtained via inductively coupled plasma optical emission spectroscopy. MF-SCGD is a promising technique with a compact instrument, low cost, low power consumption, and high discharge stability.

Authors

Institutions

Publication Details

Journal
Journal of Analytical Chemistry
Published
2025-03-01
DOI
https://doi.org/10.1134/s1061934824701946
Citations
4
Primary Topic
Laser-induced spectroscopy and plasma
Type
article
Field-Weighted Citation Impact
3.45
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of Cadmium and Zinc in Soil Samples Using Magnetic Field-Assisted Solution Cathode Glow Discharge

Quanfang Lu, Jie Yu, Kai Wang, Xiaoxia Hao et al.
4 citations
Journal of Analytical Chemistry
Laser-induced spectroscopy and plasma
3.45
article

Determination of Cadmium and Zinc in Soil Samples Using Magnetic Field-Assisted Solution Cathode Glow Discharge

Quanfang Lu, Jie Yu, Kai Wang, Xiaoxia Hao, Xuehe Li
article en
4 citations

Abstract

A magnetic field-assisted solution cathode glow discharge (MF-SCGD) was established and then applied for the detection of Cd and Zn in soil samples. In order to reveal the signal enhancement mechanism of the magnetic field, the influence of the magnetic field strength on plasma parameters, such as electron temperature and electron density, was investigated. The results showed that adding a 0.5 T magnetic field significantly reduces the red-hot degree of the Pt needle, decreases the volume of the plasma torch, extends the lifespan of the Pt needle, and widens the application range of voltage. The optimal operating parameters of MF-SCGD were identified as a 0.5 T magnetic field, 680 V discharge voltage, 3.2 mL/min solution flow rate, and pH 1.0 HNO3 as the supporting electrolyte. Under optimal conditions, the intensities of Cd and Zn signals increased by 1.7 and 1.8 times, respectively. The limits of detection were 9.1 μg/L for Cd and 12.0 μg/L for Zn. After adding a 0.5 T magnetic field, electron temperature slightly decreased while electron density increased. The plasma parameter β was found to be less than 1, indicating that signal intensity enhancement is due to magnetic confinement. The analysis results of Cd and Zn in certified reference materials and two soil samples are consistent with the certified standard and verified values obtained via inductively coupled plasma optical emission spectroscopy. MF-SCGD is a promising technique with a compact instrument, low cost, low power consumption, and high discharge stability.

Journal of Analytical ChemistryVol. 80(3)
Northwest Normal University (CN)
Life in Land
Openalex Percentile: Top 8%
Laser-induced spectroscopy and plasma
3.45
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Determination of Cadmium and Zinc in Soil Samples Using Magnetic Field-Assisted Solution Cathode Glow Discharge — Quanfang Lu, Jie Yu, et al. · Journal of Analytical Chemistry (2025) | TGRS Research Map | TGRS