Mechanism and application of thiol–disulfide redox biosensors with a fluorescence-lifetime readout

Genetically encoded biosensors with changes in fluorescence lifetime (as opposed to fluorescence intensity) can quantify small molecules in complex contexts, even in vivo. However, lifetime-readout sensors are poorly understood at a molecular level, complicating their development. Although there are many sensors that have fluorescence-intensity changes, there are currently only a few with fluorescence-lifetime changes. Here, we optimized two biosensors for thiol-disulfide redox (RoTq-Off and RoTq-On) with opposite changes in fluorescence lifetime in response to oxidation. Using biophysical approaches, we showed that the high-lifetime states of these sensors lock the chromophore more firmly in place than their low-lifetime states do. Two-photon fluorescence lifetime imaging of RoTq-On fused to a glutaredoxin (Grx1) enabled robust, straightforward monitoring of cytosolic glutathione redox state in acute mouse brain slices. The motional mechanism described here is probably common and may inform the design of other lifetime-readout sensors; the Grx1-RoTq-On fusion sensor will be useful for studying glutathione redox in physiology.

Authors

Institutions

Publication Details

Journal
Proceedings of the National Academy of Sciences
Published
2025-05-06
DOI
https://doi.org/10.1073/pnas.2503978122
Citations
5
Primary Topic
Redox biology and oxidative stress
Type
article
Field-Weighted Citation Impact
4.03

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mechanism and application of thiol–disulfide redox biosensors with a fluorescence-lifetime readout

Daniel Lim, Gary Yellen, Erica Kim, Peng Fu et al.
5 citations
Proceedings of the National Academy of Sciences
Redox biology and oxidative stress
4.03
article

Mechanism and application of thiol–disulfide redox biosensors with a fluorescence-lifetime readout

Daniel Lim, Gary Yellen, Erica Kim, Peng Fu, Paul C. Rosen, Dorothee Kern, Juan Ramón Martínez‐François, Andrew Glaser, Daniel J. Brooks
article en
5 citations

Abstract

Genetically encoded biosensors with changes in fluorescence lifetime (as opposed to fluorescence intensity) can quantify small molecules in complex contexts, even in vivo. However, lifetime-readout sensors are poorly understood at a molecular level, complicating their development. Although there are many sensors that have fluorescence-intensity changes, there are currently only a few with fluorescence-lifetime changes. Here, we optimized two biosensors for thiol-disulfide redox (RoTq-Off and RoTq-On) with opposite changes in fluorescence lifetime in response to oxidation. Using biophysical approaches, we showed that the high-lifetime states of these sensors lock the chromophore more firmly in place than their low-lifetime states do. Two-photon fluorescence lifetime imaging of RoTq-On fused to a glutaredoxin (Grx1) enabled robust, straightforward monitoring of cytosolic glutathione redox state in acute mouse brain slices. The motional mechanism described here is probably common and may inform the design of other lifetime-readout sensors; the Grx1-RoTq-On fusion sensor will be useful for studying glutathione redox in physiology.

Proceedings of the National Academy of SciencesVol. 122(19)
Harvard University (US), Massachusetts Institute of Technology (US), Brandeis University (US)
Howard Hughes Medical Institute, Department of Neurobiology, Harvard Medical School, Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, National Cancer Institute, National Institute of General Medical Sciences, National Institute of Neurological Disorders and Stroke
Clean water and sanitation
Openalex Percentile: Top 6%
Redox biology and oxidative stress
4.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.