Optical characterization of the Advanced Virgo gravitational wave detector for the O4 observing run

The Advanced Virgo Plus detector, an upgrade of the Advanced Virgo Detector, is a dual-recycled Fabry-Perot Michelson interferometer characterized by 3 km long arm cavities. The main upgrades in view of the fourth observing run (O4) were the implementation of the signal recycling cavity and the installation of the frequency-dependent squeezing system. Another upgrade was the increasing of the laser power at the input of the detector, which could lead to more severe thermal aberrations impacting the achievement of the interferometer optimal working point. Therefore, the fine-tuning of the thermal compensation system, optimized with respect to the one implemented for the O3 run, was also challenging. In order to achieve the best performance of such a sophisticated optical system, having a clear knowledge of all its optical parameters is crucial. The optical characterization of the detector in different working conditions could help in understanding its behavior and optimizing the global control system. Moreover, the characterization in different thermal conditions, i.e., different values of the input laser power or different configurations of the thermal compensation system, could provide significant guidance for the optimization of the thermal tuning. In this paper, we will describe all the methodologies adopted for the optical characterization activities performed in Advanced Virgo Plus, presenting the experimental results for all the relevant parameters obtained during the preparation of the O4 run.

Authors

Publication Details

Journal
Applied Optics
Published
2025-05-06
DOI
https://doi.org/10.1364/ao.555312
Primary Topic
Pulsars and Gravitational Waves Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optical characterization of the Advanced Virgo gravitational wave detector for the O4 observing run

Y. Guo
Applied Optics
Pulsars and Gravitational Waves Research
article

Optical characterization of the Advanced Virgo gravitational wave detector for the O4 observing run

Y. Guo
article en

Abstract

The Advanced Virgo Plus detector, an upgrade of the Advanced Virgo Detector, is a dual-recycled Fabry-Perot Michelson interferometer characterized by 3 km long arm cavities. The main upgrades in view of the fourth observing run (O4) were the implementation of the signal recycling cavity and the installation of the frequency-dependent squeezing system. Another upgrade was the increasing of the laser power at the input of the detector, which could lead to more severe thermal aberrations impacting the achievement of the interferometer optimal working point. Therefore, the fine-tuning of the thermal compensation system, optimized with respect to the one implemented for the O3 run, was also challenging. In order to achieve the best performance of such a sophisticated optical system, having a clear knowledge of all its optical parameters is crucial. The optical characterization of the detector in different working conditions could help in understanding its behavior and optimizing the global control system. Moreover, the characterization in different thermal conditions, i.e., different values of the input laser power or different configurations of the thermal compensation system, could provide significant guidance for the optimization of the thermal tuning. In this paper, we will describe all the methodologies adopted for the optical characterization activities performed in Advanced Virgo Plus, presenting the experimental results for all the relevant parameters obtained during the preparation of the O4 run.

Applied OpticsVol. 64(17)
National Science Foundation, Centres de Recerca de Catalunya, Institut des Origines de Lyon, European Commission, Fundacja na rzecz Nauki Polskiej, Fonds De La Recherche Scientifique - FNRS, Generalitat de Catalunya, Fonds Wetenschappelijk Onderzoek, Nederlandse Organisatie voor Wetenschappelijk Onderzoek, Generalitat Valenciana, Hungarian Scientific Research Fund, Centre National de la Recherche Scientifique, Aristotle University of Thessaloniki, Vlaamse regering, Istituto Nazionale di Fisica Nucleare, Science and Technology Facilities Council, Research Committee, Aristotle University of Thessaloniki, European Regional Development Fund, Agencia Estatal de Investigación
Openalex Percentile: Top 93%
Pulsars and Gravitational Waves Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.