All-Solid-State Potentiometric Sensor Based on Carbon Paste Composite for the Selective Determination of Iodide Ions

In the current study, a potentiometric all-solid-state composite ion-selective electrode for the determination of iodide ions is described. The synthesized salicylaldehyde thiosemicarbazone-mercury(II) complex (SATSC-Hg(II)) (1 : 1) was applied as the electroactive material in the electrode structure. Various composite ion-selective electrodes were prepared with different compositions, including SATSC-Hg(II), graphite, multi-walled carbon nanotubes (MWCNTs), ionic additives, and some mediators (various plasticizers or paraffin oil) to identify the most effective composite sensing layer composition exhibiting satisfactory potentiometric characteristics. The sensing layer composition consisting of 10 mg SATSC-Hg(II) complex, 26 mg dioctyl phthalate plasticizer, 5 mg MWCNTs, 4 mg methyltrioctylammonium chloride, and 65 mg graphite yielded the most favorable potentiometric performance properties. The electrode demonstrated a linear operating range of 1.0 × 10–5 to 0.1 M, a slope value of 55.2 ± 0.2 mV/decade, a detection limit of (9.0 ± 0.2) × 10–6 M, a pH operating range of 4–8, and a response time of approximately 60 s. The proposed electrode also displayed reproducible, stable, and selective potentiometric response to iodide ions. The analytical application of the electrode involved its use as an indicator electrode in the titration of iodide ions in synthetic solutions and for the determination of KI content in a pharmaceutical used for the treatment of goiter by the multiple standard addition method. Compared to polymer membrane electrodes, the renewability and reusability of the sensing surface of the proposed electrode, its suitability for miniaturization, and its robust structure offer significant advantages.

Authors

Institutions

Publication Details

Journal
Journal of Analytical Chemistry
Published
2025-03-01
DOI
https://doi.org/10.1134/s1061934824702009
Citations
3
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
2.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

All-Solid-State Potentiometric Sensor Based on Carbon Paste Composite for the Selective Determination of Iodide Ions

Fatih Çoldur, Selehattin Yılmaz
3 citations
Journal of Analytical Chemistry
Analytical Chemistry and Sensors
2.21
article

All-Solid-State Potentiometric Sensor Based on Carbon Paste Composite for the Selective Determination of Iodide Ions

Fatih Çoldur, Selehattin Yılmaz
article en
3 citations

Abstract

In the current study, a potentiometric all-solid-state composite ion-selective electrode for the determination of iodide ions is described. The synthesized salicylaldehyde thiosemicarbazone-mercury(II) complex (SATSC-Hg(II)) (1 : 1) was applied as the electroactive material in the electrode structure. Various composite ion-selective electrodes were prepared with different compositions, including SATSC-Hg(II), graphite, multi-walled carbon nanotubes (MWCNTs), ionic additives, and some mediators (various plasticizers or paraffin oil) to identify the most effective composite sensing layer composition exhibiting satisfactory potentiometric characteristics. The sensing layer composition consisting of 10 mg SATSC-Hg(II) complex, 26 mg dioctyl phthalate plasticizer, 5 mg MWCNTs, 4 mg methyltrioctylammonium chloride, and 65 mg graphite yielded the most favorable potentiometric performance properties. The electrode demonstrated a linear operating range of 1.0 × 10–5 to 0.1 M, a slope value of 55.2 ± 0.2 mV/decade, a detection limit of (9.0 ± 0.2) × 10–6 M, a pH operating range of 4–8, and a response time of approximately 60 s. The proposed electrode also displayed reproducible, stable, and selective potentiometric response to iodide ions. The analytical application of the electrode involved its use as an indicator electrode in the titration of iodide ions in synthetic solutions and for the determination of KI content in a pharmaceutical used for the treatment of goiter by the multiple standard addition method. Compared to polymer membrane electrodes, the renewability and reusability of the sensing surface of the proposed electrode, its suitability for miniaturization, and its robust structure offer significant advantages.

Journal of Analytical ChemistryVol. 80(3)
Erzincan Binali Yıldırım University (TR)
Openalex Percentile: Top 12%
Analytical Chemistry and Sensors
2.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.