Hearing Loss in High-Risk Newborns: The Effectiveness of One-stage Hearing Screening in the Neonatal Intensive Care Unit of the Jose R. Reyes Memorial Medical Center

Objective: To determine the effectiveness of a one-stage hearing screening protocol in detecting hearing loss in high risk newborns at the Neonatal Intensive Care Unit of the Jose R. Reyes Memorial Medical Center. Methods:Design: Cross-Sectional StudySetting: Tertiary Government Training HospitalPopulation: High-risk newborns admitted at the Neonatal Intensive Care Unit of the Jose R. Reyes Memorial Medical Center from March to December 2023 underwent a one stage universal newborn hearing screening protocol. Excluded from the study were patients who were admitted for less than 48 hours, without consent from their parents or guardians and babies who were not cleared medically to undergo testing, and those who presented with aural atresia and/or any physical anomaly of the head and the external ear. Results: A total of 169 babies were initially seen with 16 babies lost to follow up resulting in a final total of 153 babies (or 306 ears) tested. The refer and false positive rates were 9.8% and 8.92%, respectively, on average comparable to or even better than the two-step protocol in most studies. Sensitivity was determined to be 100% while specificity was 91.08%. The incidence of hearing loss in the study population was 19.8/1000, consistent with various study outcomes for high risk newborns. There was no reported incidence of auditory neuropathy in this study. The primary risk factors that were present in babies with hearing loss were: low birth weight, prematurity, neonatal intensive care unit admission of more than 5 days and exposure to ototoxic medications. Conclusion: The one-staged Automated Auditory Brainstem Response (AABR) is an effective and efficient newborn hearing screening protocol for high-risk newborns in the Neonatal Intensive Care Unit (NICU) setting and eventually, may be considered as an alternative hearing screening technique whenever available in this cohort. More studies about improving newborn hearing screening, cost-analysis, diagnostics and interventions of hearing loss should be pursued in implementation of the Universal Hearing Screening Law in the Philippines.

Authors

Institutions

Publication Details

Journal
Philippine Journal of Otolaryngology Head and Neck Surgery
Published
2025-04-27
DOI
https://doi.org/10.32412/pjohns.v40i1.2565
Primary Topic
Infant Development and Preterm Care
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hearing Loss in High-Risk Newborns: The Effectiveness of One-stage Hearing Screening in the Neonatal Intensive Care Unit of the Jose R. Reyes Memorial Medical Center

Christine Joyce Zambales, Elias Reala
Philippine Journal of Otolaryngology Head and Neck Surgery
Infant Development and Preterm Care
article

Hearing Loss in High-Risk Newborns: The Effectiveness of One-stage Hearing Screening in the Neonatal Intensive Care Unit of the Jose R. Reyes Memorial Medical Center

Christine Joyce Zambales, Elias Reala
article en

Abstract

Objective: To determine the effectiveness of a one-stage hearing screening protocol in detecting hearing loss in high risk newborns at the Neonatal Intensive Care Unit of the Jose R. Reyes Memorial Medical Center. Methods:Design: Cross-Sectional StudySetting: Tertiary Government Training HospitalPopulation: High-risk newborns admitted at the Neonatal Intensive Care Unit of the Jose R. Reyes Memorial Medical Center from March to December 2023 underwent a one stage universal newborn hearing screening protocol. Excluded from the study were patients who were admitted for less than 48 hours, without consent from their parents or guardians and babies who were not cleared medically to undergo testing, and those who presented with aural atresia and/or any physical anomaly of the head and the external ear. Results: A total of 169 babies were initially seen with 16 babies lost to follow up resulting in a final total of 153 babies (or 306 ears) tested. The refer and false positive rates were 9.8% and 8.92%, respectively, on average comparable to or even better than the two-step protocol in most studies. Sensitivity was determined to be 100% while specificity was 91.08%. The incidence of hearing loss in the study population was 19.8/1000, consistent with various study outcomes for high risk newborns. There was no reported incidence of auditory neuropathy in this study. The primary risk factors that were present in babies with hearing loss were: low birth weight, prematurity, neonatal intensive care unit admission of more than 5 days and exposure to ototoxic medications. Conclusion: The one-staged Automated Auditory Brainstem Response (AABR) is an effective and efficient newborn hearing screening protocol for high-risk newborns in the Neonatal Intensive Care Unit (NICU) setting and eventually, may be considered as an alternative hearing screening technique whenever available in this cohort. More studies about improving newborn hearing screening, cost-analysis, diagnostics and interventions of hearing loss should be pursued in implementation of the Universal Hearing Screening Law in the Philippines.

Philippine Journal of Otolaryngology Head and Neck SurgeryVol. 40(1)
José R. Reyes Memorial Medical Center (PH)
Openalex Percentile: Top 87%
Infant Development and Preterm Care
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.