Reproducible Transpalpebral Intraocular Pressure Sensing Enabled by Low-Energy-Barrier Ion Pumping

Elevated intraocular pressure (IOP) is a major risk factor for blindness in glaucoma patients, highlighting the critical need for continuous IOP monitoring. While traditional transpalpebral tonometers (TTs) circumvent corneal contact by adopting Goldmann applanation principles through impulsive corneal flattening forces, their measurement accuracy is inherently compromised by eyelid-induced cushion effects. In contrast, parallel-plate capacitive sensors employ constant compressive loading upon the eyelid, achieving palpebral compaction to mitigate the cushion effects. More recently, ion-pump-based capacitive sensors have emerged as promising alternatives, particularly due to their enhanced sensitivity. Nevertheless, these sensors exhibit sharp sensitivity deterioration at extended measurement ranges (0-10 kPa). This operational constraint originates from the strong hydrogen bond energies (between confining matrices and ions) and rigid block copolymer matrices' steric hindrance. To address these limitations, we developed a transpalpebral tonometer featuring low-energy-barrier ion pumps, incorporating (3-aminopropyl)triethoxysilane (APTES)-silanized liquid metal nanoparticles (LM NPs) as confining matrices and an ionic liquid as an ion donor. The low-energy barrier arises from (1) weaker hydrogen bonds between the N-H of APTES and the F of the ionic liquid and (2) reduced crystallinity in the elastomeric matrices induced by LM NPs. Our sensor achieves a sensitivity of 24.88 kPa<sup>-1</sup> with maintained linearity over 0-85 kPa. In vivo animal trials over 120 min validated its continuous IOP monitoring capability, reliably detecting elevated IOP states and demonstrating clinical potential for glaucoma management.

Authors

Institutions

Publication Details

Journal
ACS Nano
Published
2025-05-06
DOI
https://doi.org/10.1021/acsnano.5c02762
Citations
1
Primary Topic
Vestibular and auditory disorders
Type
article
Field-Weighted Citation Impact
0.84

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reproducible Transpalpebral Intraocular Pressure Sensing Enabled by Low-Energy-Barrier Ion Pumping

Benhui Hu, Qin Jiang, Yannan Wang, Xueyang Ren et al.
1 citations
ACS Nano
Vestibular and auditory disorders
0.84
article

Reproducible Transpalpebral Intraocular Pressure Sensing Enabled by Low-Energy-Barrier Ion Pumping

Benhui Hu, Qin Jiang, Yannan Wang, Xueyang Ren, Xiaodong Shao, Yang Wen, Jianqing Li, Shiyu Chen, Yongpeng Meng, Xuefei Zhu
article en
1 citations

Abstract

Elevated intraocular pressure (IOP) is a major risk factor for blindness in glaucoma patients, highlighting the critical need for continuous IOP monitoring. While traditional transpalpebral tonometers (TTs) circumvent corneal contact by adopting Goldmann applanation principles through impulsive corneal flattening forces, their measurement accuracy is inherently compromised by eyelid-induced cushion effects. In contrast, parallel-plate capacitive sensors employ constant compressive loading upon the eyelid, achieving palpebral compaction to mitigate the cushion effects. More recently, ion-pump-based capacitive sensors have emerged as promising alternatives, particularly due to their enhanced sensitivity. Nevertheless, these sensors exhibit sharp sensitivity deterioration at extended measurement ranges (0-10 kPa). This operational constraint originates from the strong hydrogen bond energies (between confining matrices and ions) and rigid block copolymer matrices' steric hindrance. To address these limitations, we developed a transpalpebral tonometer featuring low-energy-barrier ion pumps, incorporating (3-aminopropyl)triethoxysilane (APTES)-silanized liquid metal nanoparticles (LM NPs) as confining matrices and an ionic liquid as an ion donor. The low-energy barrier arises from (1) weaker hydrogen bonds between the N-H of APTES and the F of the ionic liquid and (2) reduced crystallinity in the elastomeric matrices induced by LM NPs. Our sensor achieves a sensitivity of 24.88 kPa<sup>-1</sup> with maintained linearity over 0-85 kPa. In vivo animal trials over 120 min validated its continuous IOP monitoring capability, reliably detecting elevated IOP states and demonstrating clinical potential for glaucoma management.

ACS NanoVol. 19(19)
Nanjing University of Chinese Medicine (CN), Soochow University (TW), Ministry of Health (OM), He Eye Hospital (CN), State Key Laboratory of Reproductive Medicine, Nanjing Medical University (CN)
National Natural Science Foundation of China, Nanjing Medical University, Natural Science Foundation of Jiangsu Province for Distinguished Young Scholars
Affordable and clean energy
Openalex Percentile: Top 27%
Vestibular and auditory disorders
0.84
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.