Utilization of traceable standards to validate plutonium isotopic purification and separation of plutonium progeny using AG MP-1M resin for nuclear forensic investigations

Abstract Radio-chronometric studies on plutonium (Pu) materials require independent measurement of the Pu (parent) content and isotopic distribution as well as concentration and isotopic distribution of the plutonium isotopic decay products. We performed a series of experiments to demonstrate the consistency of separations using the Lewatit MP 800 macroporous anion exchange resin and the AG MP-1M resin with traceable Pu isotopic certified reference material (CRM) standards 136, 137, 138, and 126-A. Two different mesh-sizes of the AG MP-1M resin were tested and the 50–100 mesh size resin was found to work more efficiently for the separation task. Both Lewatit and AG MP-1M resins were found to perform satisfactorily for quantitatively extracting the americium (Am) and uranium (U) progeny as well as gallium (Ga) present as a tracer in the Pu material. Both resins were effective in removing isobaric interferences from the Pu fraction used in isotopic measurements by thermal ionization mass spectrometry (TIMS). To address the co-elution of uranium and gallium, Alizarin red S (ARS) was used as a colorimetric dye to determine the behavior of UO 2 2+ and Ga 3+ on AG MP-1M resin with various acidic solutions as eluents using UV–vis spectra. Poor resolution of these peaks complicated quantitative analysis by UV–vis spectroscopy, but these results were informative in planning automated separation experiments by HPLC. LA-UR-24-28919 .

Authors

Institutions

Publication Details

Journal
Radiochimica Acta
Published
2025-05-05
DOI
https://doi.org/10.1515/ract-2025-0012
Primary Topic
Radioactive contamination and transfer
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Utilization of traceable standards to validate plutonium isotopic purification and separation of plutonium progeny using AG MP-1M resin for nuclear forensic investigations

K. J. Mathew, James C. Gilhula, Angela C. Olson, Nicholas Butterfield
Radiochimica Acta
Radioactive contamination and transfer
article

Utilization of traceable standards to validate plutonium isotopic purification and separation of plutonium progeny using AG MP-1M resin for nuclear forensic investigations

K. J. Mathew, James C. Gilhula, Angela C. Olson, Nicholas Butterfield
article en

Abstract

Abstract Radio-chronometric studies on plutonium (Pu) materials require independent measurement of the Pu (parent) content and isotopic distribution as well as concentration and isotopic distribution of the plutonium isotopic decay products. We performed a series of experiments to demonstrate the consistency of separations using the Lewatit MP 800 macroporous anion exchange resin and the AG MP-1M resin with traceable Pu isotopic certified reference material (CRM) standards 136, 137, 138, and 126-A. Two different mesh-sizes of the AG MP-1M resin were tested and the 50–100 mesh size resin was found to work more efficiently for the separation task. Both Lewatit and AG MP-1M resins were found to perform satisfactorily for quantitatively extracting the americium (Am) and uranium (U) progeny as well as gallium (Ga) present as a tracer in the Pu material. Both resins were effective in removing isobaric interferences from the Pu fraction used in isotopic measurements by thermal ionization mass spectrometry (TIMS). To address the co-elution of uranium and gallium, Alizarin red S (ARS) was used as a colorimetric dye to determine the behavior of UO 2 2+ and Ga 3+ on AG MP-1M resin with various acidic solutions as eluents using UV–vis spectra. Poor resolution of these peaks complicated quantitative analysis by UV–vis spectroscopy, but these results were informative in planning automated separation experiments by HPLC. LA-UR-24-28919 .

Radiochimica ActaVol. 113(7)
Los Alamos National Laboratory (US)
Glenn T. Seaborg Institute, Civil Aviation Administration of China, Laboratory Directed Research and Development, Los Alamos National Laboratory
Openalex Percentile: Top 90%
Radioactive contamination and transfer
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.