Preclinical development of a continuous fetal lactate biosensor to detect acidosis

Abstract Introduction Accurate detection of fetal acidosis in labor is an unmet clinical need. Objectives of this study are: To run a pilot validation of a subcutaneous biosensor for continuous lactate monitoring (CLM) to detect acidosis in a fetal lamb model of asphyxia. Assess the feasibility of the CLM biosensor for intrapartum fetal monitoring by correlating sensor‐detected lactate levels with contemporaneously collected blood lactate values. Method Ewes ( n = 3) with singleton pregnancy were anesthetized and the lamb's head was exteriorized. Multiple biosensors were placed onto the lamb scalp, with electrical current outputs captured. Jugular venous blood samples were collected at regular intervals across the protocol, and lactate and other physiological parameters were recorded. After baseline, the umbilical cord was occluded for 10 min, with recordings continuing over at least 3 h during recovery. Results Nine biosensors were tested across three animals. Six of the nine had a clear response to lactate rise from an acute hypoxic event, with five of these having strong correlation ( R 2 > 0.93). These five sensors responded to change in venous lactate from as low as 1.6 mmol/L up to 8.4 mmol/L over a range of pH (7.04‐7.38) and p v O 2 (1.6‐23.5 mmHg) over 5.5 h, demonstrating the utility of the biosensor in monitoring in‐vivo lactate levels. Conclusion This study demonstrates the capability of an innovative subcutaneous biosensor for CLM in detecting early signs of fetal lactic acidosis, highlighted by the strong correlation between sensor current and venous blood lactate levels. This technology has the potential to enable continuous fetal lactate measurement, with the ability to revolutionize intrapartum care and improve neonatal outcomes by enabling crucial early detection and management of fetal asphyxia during labor and delivery.

Authors

Institutions

Publication Details

Journal
Pregnancy
Published
2025-05-01
DOI
https://doi.org/10.1002/pmf2.70017
Primary Topic
Neonatal and fetal brain pathology
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preclinical development of a continuous fetal lactate biosensor to detect acidosis

Arjun Kaushik, AM Gurney, Gabrielle C. Musk, Michael Ross et al.
Pregnancy
Neonatal and fetal brain pathology
article

Preclinical development of a continuous fetal lactate biosensor to detect acidosis

Arjun Kaushik, AM Gurney, Gabrielle C. Musk, Michael Ross, Lee J. Hubble, Henry C. Powell, Y. Jane Choi, Michael Challenor, Rajaganesh Rajagopalan, J. Jane Pillow, Helen Kershaw, Jonathan Morris, Chaitya Shah, Hassan Mahmood
article en

Abstract

Abstract Introduction Accurate detection of fetal acidosis in labor is an unmet clinical need. Objectives of this study are: To run a pilot validation of a subcutaneous biosensor for continuous lactate monitoring (CLM) to detect acidosis in a fetal lamb model of asphyxia. Assess the feasibility of the CLM biosensor for intrapartum fetal monitoring by correlating sensor‐detected lactate levels with contemporaneously collected blood lactate values. Method Ewes ( n = 3) with singleton pregnancy were anesthetized and the lamb's head was exteriorized. Multiple biosensors were placed onto the lamb scalp, with electrical current outputs captured. Jugular venous blood samples were collected at regular intervals across the protocol, and lactate and other physiological parameters were recorded. After baseline, the umbilical cord was occluded for 10 min, with recordings continuing over at least 3 h during recovery. Results Nine biosensors were tested across three animals. Six of the nine had a clear response to lactate rise from an acute hypoxic event, with five of these having strong correlation ( R 2 > 0.93). These five sensors responded to change in venous lactate from as low as 1.6 mmol/L up to 8.4 mmol/L over a range of pH (7.04‐7.38) and p v O 2 (1.6‐23.5 mmHg) over 5.5 h, demonstrating the utility of the biosensor in monitoring in‐vivo lactate levels. Conclusion This study demonstrates the capability of an innovative subcutaneous biosensor for CLM in detecting early signs of fetal lactic acidosis, highlighted by the strong correlation between sensor current and venous blood lactate levels. This technology has the potential to enable continuous fetal lactate measurement, with the ability to revolutionize intrapartum care and improve neonatal outcomes by enabling crucial early detection and management of fetal asphyxia during labor and delivery.

PregnancyVol. 1(3)
The University of Western Australia (AU)
Australian Government, Cooperative Research Centres, Australian Government Department of Industry, Government of Western Australia, National Health and Medical Research Council
Openalex Percentile: Top 87%
Neonatal and fetal brain pathology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.