The haemodynamic effects of pneumoperitoneum on pulse pressure variation – a prospective, observational study

The effects of pneumoperitoneum on dynamic predictors of fluid responsiveness such as pulse pressure variation (PPV) remain uncertain. This uncertainty arises from potentially opposing physiological mechanisms that affect cardiovascular dynamics during conditions with increased intra-abdominal pressure (IAP). Deriving PPV with high precision during induction of pneumoperitoneum may provide new insights into the complex relationship between intra-abdominal pressure changes and PPV. The hypothesis was that PPV derived from a generalised additive model (PPV<sub>GAM</sub>) would increase with the induction of pneumoperitoneum and the associacted increase in IAP. This was a prospective, observational study in patients undergoing oesophagectomy. Before and after induction of pneumoperitoneum, haemodynamic variables including PPV and stroke volume variation (SVV) were recorded with the Hemosphere monitor. PPV<sub>GAM</sub> was estimated offline from the arterial blood pressure curve. A total of 34 patients were included in the final analysis. PPV<sub>GAM</sub> increased by a factor of 1.49 (95% CI: 1.25-1.77) as intra-abdominal pressure increased from baseline to 12 mmHg. SVV and PPV from the HemoSphere monitor increased with a factor of 1.25 (95% CI: 1.13-1.39, p < 0.001) and 1.14 (95% CI: 1.00-1.29, p = 0.048), respectively. PPV derived from a generalised additive model increased approximately 50% from the induction of pneumoperitoneum to an IAP of 12 mmHg. PPV and SVV derived from the Hemosphere monitor also increased signicantly.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Monitoring and Computing
Published
2025-05-05
DOI
https://doi.org/10.1007/s10877-025-01300-3
Citations
2
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
4.01

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The haemodynamic effects of pneumoperitoneum on pulse pressure variation – a prospective, observational study

Peter Juhl‐Olsen, Henrik Lynge Hovgaard, Johannes Enevoldsen, Simon Tilma Vistisen et al.
2 citations
Journal of Clinical Monitoring and Computing
Hemodynamic Monitoring and Therapy
4.01
article

The haemodynamic effects of pneumoperitoneum on pulse pressure variation – a prospective, observational study

Peter Juhl‐Olsen, Henrik Lynge Hovgaard, Johannes Enevoldsen, Simon Tilma Vistisen, Frank Vincenzo de Paoli
article en
2 citations

Abstract

The effects of pneumoperitoneum on dynamic predictors of fluid responsiveness such as pulse pressure variation (PPV) remain uncertain. This uncertainty arises from potentially opposing physiological mechanisms that affect cardiovascular dynamics during conditions with increased intra-abdominal pressure (IAP). Deriving PPV with high precision during induction of pneumoperitoneum may provide new insights into the complex relationship between intra-abdominal pressure changes and PPV. The hypothesis was that PPV derived from a generalised additive model (PPV<sub>GAM</sub>) would increase with the induction of pneumoperitoneum and the associacted increase in IAP. This was a prospective, observational study in patients undergoing oesophagectomy. Before and after induction of pneumoperitoneum, haemodynamic variables including PPV and stroke volume variation (SVV) were recorded with the Hemosphere monitor. PPV<sub>GAM</sub> was estimated offline from the arterial blood pressure curve. A total of 34 patients were included in the final analysis. PPV<sub>GAM</sub> increased by a factor of 1.49 (95% CI: 1.25-1.77) as intra-abdominal pressure increased from baseline to 12 mmHg. SVV and PPV from the HemoSphere monitor increased with a factor of 1.25 (95% CI: 1.13-1.39, p < 0.001) and 1.14 (95% CI: 1.00-1.29, p = 0.048), respectively. PPV derived from a generalised additive model increased approximately 50% from the induction of pneumoperitoneum to an IAP of 12 mmHg. PPV and SVV derived from the Hemosphere monitor also increased signicantly.

Journal of Clinical Monitoring and ComputingVol. 39(5)
Aarhus University (DK), Aarhus University Hospital (DK)
Aarhus Universitetshospital
Good health and well-being
Openalex Percentile: Top 8%
Hemodynamic Monitoring and Therapy
4.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.