UJI VALIDASI METODE DAN PENETAPAN KADAR RANITIDIN DALAM SEDIAAN TABLET SECARA SPEKTROFOTOMETRI UV

This study aims to determine the levels of ranitidine in generic and trade name tablet preparations by UV spectrophotometry. Based on the results obtained linearity value of r = 0.9999 with limit of detection (LOD) 0.1667 ppm and limit of quantitation (LOQ) 0.5558 ppm. Precision obtained RSD results of 0.641% and in accuracy obtained % recovery at 3 concentrations of 9, 12 and 15 ppm respectively 101.05; 100.63; and 100.33%. The results of the determination of levels in ranitidine tablet preparations with five generic tablets and five trade name tablets have met the requirements for levels in medicinal preparations for ranitidine tablet preparations according to the Indonesian Pharmacopoeia VI Edition, which contains ranitidine not less than 90.0% and not more than 110.0%. It can be concluded that the UV spectrophotometric method used in the study has met the parameters set in the validation test so that this method can be applied to the analysis of determining ranitidine levels in a laboratory. Keywords: Ranitidine, UV Spectrophotometry, Method validation

Authors

Institutions

Publication Details

Journal
JFL Jurnal Farmasi Lampung
Published
2024-12-11
DOI
https://doi.org/10.37090/jfl.v13i2.1805
Primary Topic
Medicinal Plant Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

UJI VALIDASI METODE DAN PENETAPAN KADAR RANITIDIN DALAM SEDIAAN TABLET SECARA SPEKTROFOTOMETRI UV

Rahma Dona, Armon Fernando, Musyirna Rahmah Nasution, Tilar Eka Widia Ningrum et al.
JFL Jurnal Farmasi Lampung
Medicinal Plant Research
article

UJI VALIDASI METODE DAN PENETAPAN KADAR RANITIDIN DALAM SEDIAAN TABLET SECARA SPEKTROFOTOMETRI UV

Rahma Dona, Armon Fernando, Musyirna Rahmah Nasution, Tilar Eka Widia Ningrum, Ilham Syahbandi, Jesy Milianty
article en

Abstract

This study aims to determine the levels of ranitidine in generic and trade name tablet preparations by UV spectrophotometry. Based on the results obtained linearity value of r = 0.9999 with limit of detection (LOD) 0.1667 ppm and limit of quantitation (LOQ) 0.5558 ppm. Precision obtained RSD results of 0.641% and in accuracy obtained % recovery at 3 concentrations of 9, 12 and 15 ppm respectively 101.05; 100.63; and 100.33%. The results of the determination of levels in ranitidine tablet preparations with five generic tablets and five trade name tablets have met the requirements for levels in medicinal preparations for ranitidine tablet preparations according to the Indonesian Pharmacopoeia VI Edition, which contains ranitidine not less than 90.0% and not more than 110.0%. It can be concluded that the UV spectrophotometric method used in the study has met the parameters set in the validation test so that this method can be applied to the analysis of determining ranitidine levels in a laboratory. Keywords: Ranitidine, UV Spectrophotometry, Method validation

JFL Jurnal Farmasi LampungVol. 13(2)
Universitas Patria Artha (ID)
Openalex Percentile: Top 84%
Medicinal Plant Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

UJI VALIDASI METODE DAN PENETAPAN KADAR RANITIDIN DALAM SEDIAAN TABLET SECARA SPEKTROFOTOMETRI UV — Rahma Dona, Armon Fernando, et al. · JFL Jurnal Farmasi Lampung (2024) | TGRS Research Map | TGRS