Performance Evaluation and Validation of Neodocs Hb Testing Point-Of-Care Device with Standard Laboratory Analyzer

Accurate Hb measurement is crucial for diagnosing and managing anemia. In India, anemia represents a significant public health crisis, affecting over 40% of the population and necessitating comprehensive interventions to address its widespread impact. In April 2018, the Indian Ministry of Health and Family Welfare launched the Anemia Mukt Bharat (AMB) strategy as a comprehensive national initiative to address and significantly reduce the substantial and pervasive public health issue of anemia within the country. Pointof-care testing (POCT) of anemia using digital hemoglobinometers and treatment is one of the primary interventions under AMB. To improve clinical decision-making and enable large-scale screening initiatives, our organization designed an innovative point-of-care Hb testing device that provides quick, accurate results. The analytical performance was assessed through a validation study performed at the Dr. Jariwala Laboratory, a NABL-accredited facility, ensuring the reliability and accuracy of the results. A total 3 batches with 30 samples provided capillary blood samples which underwent simultaneous analysis using the Neodocs (ND)-Hb device and a standard laboratory haematology analyzer (Mindray BC-780 Haematology System) to ensure accurate and comparable results. The device exhibited high precision and minimal variability across different hemoglobin ranges, demonstrating strength in detecting moderate-to-severe anemia. No significant operational errors or user-related issues were reported during the study, highlighting the device's usability in point-of-caresettings.Further, the results were reproducible with maximum standard deviation 0.57, suitable for use on regular patient's sample.

Authors

Publication Details

Journal
International Journal of Science and Research (IJSR)
Published
2025-05-05
DOI
https://doi.org/10.21275/sr25429171450
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Evaluation and Validation of Neodocs Hb Testing Point-Of-Care Device with Standard Laboratory Analyzer

Shubham Munde, Nikunj Malpani, Pratik Lodha, Anurag Meena
International Journal of Science and Research (IJSR)
Non-Invasive Vital Sign Monitoring
article

Performance Evaluation and Validation of Neodocs Hb Testing Point-Of-Care Device with Standard Laboratory Analyzer

Shubham Munde, Nikunj Malpani, Pratik Lodha, Anurag Meena
article en

Abstract

Accurate Hb measurement is crucial for diagnosing and managing anemia. In India, anemia represents a significant public health crisis, affecting over 40% of the population and necessitating comprehensive interventions to address its widespread impact. In April 2018, the Indian Ministry of Health and Family Welfare launched the Anemia Mukt Bharat (AMB) strategy as a comprehensive national initiative to address and significantly reduce the substantial and pervasive public health issue of anemia within the country. Pointof-care testing (POCT) of anemia using digital hemoglobinometers and treatment is one of the primary interventions under AMB. To improve clinical decision-making and enable large-scale screening initiatives, our organization designed an innovative point-of-care Hb testing device that provides quick, accurate results. The analytical performance was assessed through a validation study performed at the Dr. Jariwala Laboratory, a NABL-accredited facility, ensuring the reliability and accuracy of the results. A total 3 batches with 30 samples provided capillary blood samples which underwent simultaneous analysis using the Neodocs (ND)-Hb device and a standard laboratory haematology analyzer (Mindray BC-780 Haematology System) to ensure accurate and comparable results. The device exhibited high precision and minimal variability across different hemoglobin ranges, demonstrating strength in detecting moderate-to-severe anemia. No significant operational errors or user-related issues were reported during the study, highlighting the device's usability in point-of-caresettings.Further, the results were reproducible with maximum standard deviation 0.57, suitable for use on regular patient's sample.

International Journal of Science and Research (IJSR)Vol. 14(5)
Openalex Percentile: Top 91%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.