Dual-beam photothermal material trace detection method based on self-mixing interference

In this paper, a dual-beam photothermal self-mixing substance trace detection system is proposed. The crystal violet (CV) solution of the sample undergoes a thermal lens effect under the action of pump photoperiod excitation, and the refractive index changes cause the deviation of the probe beam, and the self-mixing interference (SMI) effect occurs when the modulated light returns to the cavity. By combining theoretical and experimental results, the power fluctuation of the SMI signal caused by the thermo-optic effect is linearly related to CV concentration and other parameters. At an excitation power of 24 mW, the detection limit can reach 8.0×10<sup>-8</sup><i>m</i><i>o</i><i>l</i>/<i>L</i>. This method does not require labeling or complex CV pretreatment and has high sensitivity and flexibility, providing a guide for CV characterization in biological, environmental, and pharmaceutical research.

Authors

Institutions

Publication Details

Journal
Applied Optics
Published
2025-05-05
DOI
https://doi.org/10.1364/ao.560828
Citations
1
Primary Topic
Advanced Optical Sensing Technologies
Type
article
Field-Weighted Citation Impact
1.19

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dual-beam photothermal material trace detection method based on self-mixing interference

Daming Dong, Yunlong Zhi, Jigang Tong, Hui Zhao et al.
1 citations
Applied Optics
Advanced Optical Sensing Technologies
1.19
article

Dual-beam photothermal material trace detection method based on self-mixing interference

Daming Dong, Yunlong Zhi, Jigang Tong, Hui Zhao, Zhao Yan, Chunling Tu
article en
1 citations

Abstract

In this paper, a dual-beam photothermal self-mixing substance trace detection system is proposed. The crystal violet (CV) solution of the sample undergoes a thermal lens effect under the action of pump photoperiod excitation, and the refractive index changes cause the deviation of the probe beam, and the self-mixing interference (SMI) effect occurs when the modulated light returns to the cavity. By combining theoretical and experimental results, the power fluctuation of the SMI signal caused by the thermo-optic effect is linearly related to CV concentration and other parameters. At an excitation power of 24 mW, the detection limit can reach 8.0×10<sup>-8</sup><i>m</i><i>o</i><i>l</i>/<i>L</i>. This method does not require labeling or complex CV pretreatment and has high sensitivity and flexibility, providing a guide for CV characterization in biological, environmental, and pharmaceutical research.

Applied OpticsVol. 64(16)
Tianjin University of Technology (CN), Tshwane University of Technology (ZA), Beijing Academy of Agricultural and Forestry Sciences (CN)
National Natural Science Foundation of China
Climate action
Openalex Percentile: Top 22%
Advanced Optical Sensing Technologies
1.19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.