Tests on Short Outer Tube–Stiffened CFDST Columns: Effect of Stiffener Distribution on Axial Performance

Previous studies on concrete-filled double-skin tubular columns (CFDSTCs) have demonstrated a superior axial performance when outer steel tubes are reinforced with steel stiffeners. As a result, recommendations for stiffener design, specifically focusing on its cross-sectional area parameter, were proposed. However, as the steel tube diameter increases, increasing only the stiffener area (while maintaining a constant number of stiffeners) may satisfy the proposed recommendation, yet it could be ineffective in serving the intended purpose. Subsequently tests were conducted to address this issue through experimental investigation, as no tests or data are available for the optimal stiffener distribution in CFDSTCs, in continuation with the previous experimental research on outer tube–stiffened CFDSTs. The key focus of this study is to assess the impact of stiffener distribution in outer tubes of circular CFDSTs, by varying the stiffener width, stiffener number, outer tube diameter and stiffener spacing in terms of subpanel width. Failure characteristics in steel tubes, concrete core, peak loads, axial load–strain response, hoop-strain behavior, confined concrete strength, strength index and ductility index were the different performance indicators analyzed. Lastly, the peak test strengths were compared with those predicted by available design models, revealing inconsistencies in these approaches. The test findings highlight the significant impact of stiffener distribution on axial performance across all indicators, especially on the axial strength (up to 24%) and confined concrete strength (up to 28%). Consequently, results from a modified design model that integrated the improved confined concrete strength of short circular outer tube–stiffened CFDSTCs agreed well with the test results.

Authors

Institutions

Publication Details

Journal
Journal of Structural Engineering
Published
2025-05-05
DOI
https://doi.org/10.1061/jsendh.steng-14487
Citations
4
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
3.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Tests on Short Outer Tube–Stiffened CFDST Columns: Effect of Stiffener Distribution on Axial Performance

Javed Ahmad Bhat, Fayaz A. Sofi, M. Adil Dar, Aamir Hassan
4 citations
Journal of Structural Engineering
Structural Load-Bearing Analysis
3.81
article

Tests on Short Outer Tube–Stiffened CFDST Columns: Effect of Stiffener Distribution on Axial Performance

Javed Ahmad Bhat, Fayaz A. Sofi, M. Adil Dar, Aamir Hassan
article en
4 citations

Abstract

Previous studies on concrete-filled double-skin tubular columns (CFDSTCs) have demonstrated a superior axial performance when outer steel tubes are reinforced with steel stiffeners. As a result, recommendations for stiffener design, specifically focusing on its cross-sectional area parameter, were proposed. However, as the steel tube diameter increases, increasing only the stiffener area (while maintaining a constant number of stiffeners) may satisfy the proposed recommendation, yet it could be ineffective in serving the intended purpose. Subsequently tests were conducted to address this issue through experimental investigation, as no tests or data are available for the optimal stiffener distribution in CFDSTCs, in continuation with the previous experimental research on outer tube–stiffened CFDSTs. The key focus of this study is to assess the impact of stiffener distribution in outer tubes of circular CFDSTs, by varying the stiffener width, stiffener number, outer tube diameter and stiffener spacing in terms of subpanel width. Failure characteristics in steel tubes, concrete core, peak loads, axial load–strain response, hoop-strain behavior, confined concrete strength, strength index and ductility index were the different performance indicators analyzed. Lastly, the peak test strengths were compared with those predicted by available design models, revealing inconsistencies in these approaches. The test findings highlight the significant impact of stiffener distribution on axial performance across all indicators, especially on the axial strength (up to 24%) and confined concrete strength (up to 28%). Consequently, results from a modified design model that integrated the improved confined concrete strength of short circular outer tube–stiffened CFDSTCs agreed well with the test results.

Journal of Structural EngineeringVol. 151(7)
Institut Teknologi dan Sains Mandala
Openalex Percentile: Top 7%
Structural Load-Bearing Analysis
3.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Tests on Short Outer Tube–Stiffened CFDST Columns: Effect of Stiffener Distribution on Axial Performance — Javed Ahmad Bhat, Fayaz A. Sofi, et al. · Journal of Structural Engineering (2025) | TGRS Research Map | TGRS