Comparative evaluation of two autotransfusion devices in a 72h survival swine model of surgically induced controlled splenic bleeding

Autotransfusion is a key strategy in hemorrhagic surgical procedures, reducing risks like disease transmission and immunosuppression due to allogenic transfusion. While conventional devices efficiently process red blood cells by centrifugation, they don't address complications requiring additional platelet transfusions. The innovative same™ device (i-SEP, France), utilizing hollow-fiber filtration, preserves both red blood cells and platelets without damaging cell integrity. This study designed as a prospective randomized controlled trial compared cell concentration and washout performances of two autotransfusion devices, a preclinical version of same™, the conventional centrifugation-based Xtra® (LivaNova, UK); and effects of retransfusion versus no transfusion in 21 Yucatan minipigs submitted to a surgically induced controlled splenic bleeding. Animals were divided into three groups (no-transfusion control group, same group and xtra group) and monitored postoperatively for 72 hours during which serial animal blood samples were collected for hematologic, biochemical and coagulation analyses and tests. Both autotransfusion devices showed high performances in red blood cell yields and concentrations, with a significant superiority of same™ device to preserve platelets. Animals from same and xtra groups retrieved similar rheological profiles and maintained a normal hematocrit compared to no-transfusion control animals. Coagulation profiles stayed within normal range in all groups. No adverse event on animals nor post-mortem sign of thrombosis were identified on autotransfused animals. The same™ device that can therefore be considered as an interesting alternative to conventional centrifugation-based devices. Further experiments are needed to provide evidence of platelets autotransfusion benefits in massive hemorrhagic procedures.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2025-05-05
DOI
https://doi.org/10.1371/journal.pone.0322568
Citations
2
Primary Topic
Trauma, Hemostasis, Coagulopathy, Resuscitation
Type
article
Field-Weighted Citation Impact
3.09

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative evaluation of two autotransfusion devices in a 72h survival swine model of surgically induced controlled splenic bleeding

Patricia Forest-Villegas, Mallorie Dépond, Audrey Lafragette, Gwenola Touzot‐Jourde et al.
2 citations
PLoS ONE
Trauma, Hemostasis, Coagulopathy, Resuscitation
3.09
article

Comparative evaluation of two autotransfusion devices in a 72h survival swine model of surgically induced controlled splenic bleeding

Patricia Forest-Villegas, Mallorie Dépond, Audrey Lafragette, Gwenola Touzot‐Jourde, Alberto Castelli, Marine Bruneau, Benoît Decouture, Olivier Gauthier, Chloé Libaud
article en
2 citations

Abstract

Autotransfusion is a key strategy in hemorrhagic surgical procedures, reducing risks like disease transmission and immunosuppression due to allogenic transfusion. While conventional devices efficiently process red blood cells by centrifugation, they don't address complications requiring additional platelet transfusions. The innovative same™ device (i-SEP, France), utilizing hollow-fiber filtration, preserves both red blood cells and platelets without damaging cell integrity. This study designed as a prospective randomized controlled trial compared cell concentration and washout performances of two autotransfusion devices, a preclinical version of same™, the conventional centrifugation-based Xtra® (LivaNova, UK); and effects of retransfusion versus no transfusion in 21 Yucatan minipigs submitted to a surgically induced controlled splenic bleeding. Animals were divided into three groups (no-transfusion control group, same group and xtra group) and monitored postoperatively for 72 hours during which serial animal blood samples were collected for hematologic, biochemical and coagulation analyses and tests. Both autotransfusion devices showed high performances in red blood cell yields and concentrations, with a significant superiority of same™ device to preserve platelets. Animals from same and xtra groups retrieved similar rheological profiles and maintained a normal hematocrit compared to no-transfusion control animals. Coagulation profiles stayed within normal range in all groups. No adverse event on animals nor post-mortem sign of thrombosis were identified on autotransfused animals. The same™ device that can therefore be considered as an interesting alternative to conventional centrifugation-based devices. Further experiments are needed to provide evidence of platelets autotransfusion benefits in massive hemorrhagic procedures.

PLoS ONEVol. 20(5)
Inserm (FR), École Nationale Vétérinaire d'Alfort (FR), The Enteric Nervous System in Gut and Brain Disorders (FR), Oniris (FR), Nantes Université (FR)
Bpifrance
Good health and well-being
Openalex Percentile: Top 10%
Trauma, Hemostasis, Coagulopathy, Resuscitation
3.09
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.