The value of high-pitch scanning with Sn100kV and ADMIRE in CT examination of tuberculous destroyed lung: Identifying the optimal combination for ultra-low-dose imaging
The combination of high-pitch scanning with Sn100kV and ADMIRE can be effectively used for ultra-low-dose CT examination of the tuberculous destroyed lung, obtaining satisfactory diagnostic images and reducing the occurrence of motion artifacts. This technique achieves conventional diagnostic outcomes at ultra-low doses and significantly reduces motion artifacts, holding significant potential and value for widespread clinical application in CT examinations for patients with tuberculous disfigured lung.