Shape Reconstruction for Flexible Robot Using FBG Sensor

Flexible robots have shown great potential in medical applications. Highly accurate shape perception methods for flexible robots can effectively enhance their operability in complex environments. In this paper, an improved 3D shape reconstruction algorithm based on the Frenet-Serret formulas is proposed to reconstruct the robot curve. The complex 3D curve shape can be reconstructed by segmenting and stitching the curvature and torsion information collected by fiber Bragg grating sensor. The calibration experiments prove the reconstruction accuracy and calculation speed of the algorithm. The shape sensor for the flexible robot is fabricated, 2D and 3D shape sensing experiments are conducted. The average Euclidean errors of the reconstructed curve endpoints are 1.120 mm and 1.358 mm, and the average Frey interval distances are 1.922 mm and 2.533 mm, respectively. The experimental results showed that the designed shape sensor has high accuracy to meet the actual sensing requirements.

Authors

Publication Details

Journal
IEEE Instrumentation & Measurement Magazine
Published
2025-05-01
DOI
https://doi.org/10.1109/mim.2025.10982090
Primary Topic
Soft Robotics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Shape Reconstruction for Flexible Robot Using FBG Sensor

Qi Jiang, Feiwen Wang, Yingxuan Zhang
IEEE Instrumentation & Measurement Magazine
Soft Robotics and Applications
article

Shape Reconstruction for Flexible Robot Using FBG Sensor

Qi Jiang, Feiwen Wang, Yingxuan Zhang
article en

Abstract

Flexible robots have shown great potential in medical applications. Highly accurate shape perception methods for flexible robots can effectively enhance their operability in complex environments. In this paper, an improved 3D shape reconstruction algorithm based on the Frenet-Serret formulas is proposed to reconstruct the robot curve. The complex 3D curve shape can be reconstructed by segmenting and stitching the curvature and torsion information collected by fiber Bragg grating sensor. The calibration experiments prove the reconstruction accuracy and calculation speed of the algorithm. The shape sensor for the flexible robot is fabricated, 2D and 3D shape sensing experiments are conducted. The average Euclidean errors of the reconstructed curve endpoints are 1.120 mm and 1.358 mm, and the average Frey interval distances are 1.922 mm and 2.533 mm, respectively. The experimental results showed that the designed shape sensor has high accuracy to meet the actual sensing requirements.

IEEE Instrumentation & Measurement MagazineVol. 28(3)
Sustainable cities and communities
Openalex Percentile: Top 91%
Soft Robotics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Shape Reconstruction for Flexible Robot Using FBG Sensor — Qi Jiang, Feiwen Wang, et al. · IEEE Instrumentation & Measurement Magazine (2025) | TGRS Research Map | TGRS