Automated Cyclic Testing of Prosthetic Knee Joints Using a 4-Axis Robotic Arm: Enhancing Biomechatronics and Human-Machine Interaction

The complex nature of knee joints makes designing and testing prosthetic replacements challenging. The ISO 10328:2016 standard requires rigorous static, constant, and cyclic force testing, which involves high forces and variable angles, adding to the complexity. Current prosthetic knee testers are often expensive, high-maintenance, and space-consuming, and many do not meet the ISO 10328:2016 requirements. This paper reviews existing testing methodologies and identifies their limitations. It then introduces a novel solution using a 4-axis robotic arm and a scaled prosthetic knee joint to perform the ISO 10328:2016 tests as a proof of concept. This approach aims to provide an affordable, low-maintenance, and compact testing method, advancing the field of biomechatronics and human-machine interaction.

Authors

Institutions

Publication Details

Published
2025-02-12
DOI
https://doi.org/10.1109/icara64554.2025.10977690
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated Cyclic Testing of Prosthetic Knee Joints Using a 4-Axis Robotic Arm: Enhancing Biomechatronics and Human-Machine Interaction

Michael Rose, Aghil Jafari, Appolinaire Etoundi, Dominic Pennycook et al.
1 links
Muscle activation and electromyography studies
article

Automated Cyclic Testing of Prosthetic Knee Joints Using a 4-Axis Robotic Arm: Enhancing Biomechatronics and Human-Machine Interaction

Michael Rose, Aghil Jafari, Appolinaire Etoundi, Dominic Pennycook, Maryam Atoofi
article en

Abstract

The complex nature of knee joints makes designing and testing prosthetic replacements challenging. The ISO 10328:2016 standard requires rigorous static, constant, and cyclic force testing, which involves high forces and variable angles, adding to the complexity. Current prosthetic knee testers are often expensive, high-maintenance, and space-consuming, and many do not meet the ISO 10328:2016 requirements. This paper reviews existing testing methodologies and identifies their limitations. It then introduces a novel solution using a 4-axis robotic arm and a scaled prosthetic knee joint to perform the ISO 10328:2016 tests as a proof of concept. This approach aims to provide an affordable, low-maintenance, and compact testing method, advancing the field of biomechatronics and human-machine interaction.

University of the West of England (GB)
Openalex Percentile: Top 91%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.