Control Techniques for TCM-Based Buck Active Power Decoupler Without DC-Link Current Sampling

Active power decoupling (APD) circuits are frequently employed to suppress dc-side second harmonic of single-phase inverters. Triangular current mode (TCM) control enables the realization of zero-voltage switching. However, due to the considerable current ripple and variable switching frequency under TCM modulation, it is quite difficult to accurately detect, sample and control the inductor current. In this article, based on a buck APD circuit under TCM modulation, a voltage closed-loop control strategy combined with time prediction method is proposed, which eliminates the need to sample the dc bus current and the decoupling inductor current. The approach achieves effective harmonic suppression and full-range soft switching with easy control. In addition, the effect of turning off the APD circuit for a short period of time on switching frequency and harmonic suppression is explored. The proposed strategy is validated on a 600 W experimental prototype.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Industrial Electronics
Published
2025-05-05
DOI
https://doi.org/10.1109/tie.2025.3561775
Primary Topic
Multilevel Inverters and Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Control Techniques for TCM-Based Buck Active Power Decoupler Without DC-Link Current Sampling

Chaofan Wei, Rui Li, Ruogu Yao
IEEE Transactions on Industrial Electronics
Multilevel Inverters and Converters
article

Control Techniques for TCM-Based Buck Active Power Decoupler Without DC-Link Current Sampling

Chaofan Wei, Rui Li, Ruogu Yao
article en

Abstract

Active power decoupling (APD) circuits are frequently employed to suppress dc-side second harmonic of single-phase inverters. Triangular current mode (TCM) control enables the realization of zero-voltage switching. However, due to the considerable current ripple and variable switching frequency under TCM modulation, it is quite difficult to accurately detect, sample and control the inductor current. In this article, based on a buck APD circuit under TCM modulation, a voltage closed-loop control strategy combined with time prediction method is proposed, which eliminates the need to sample the dc bus current and the decoupling inductor current. The approach achieves effective harmonic suppression and full-range soft switching with easy control. In addition, the effect of turning off the APD circuit for a short period of time on switching frequency and harmonic suppression is explored. The proposed strategy is validated on a 600 W experimental prototype.

IEEE Transactions on Industrial ElectronicsVol. 72(11)
Shanghai Jiao Tong University (CN)
Affordable and clean energy
Openalex Percentile: Top 92%
Multilevel Inverters and Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.