Native Flow-Induced Dispersion Analysis – Mass Spectrometry Enables Automated, Multiplexed Ligand Screening from Conventional, Nonvolatile Buffers

Native electrospray ionization mass spectrometry has become an important method for the discovery and validation of noncovalent ligands for therapeutic targets. As a label-free method combining high sensitivity and chemical specificity, it is ideally suited for this application. However, the performance of the method is severely impacted by the presence of nonvolatile buffers and salts, and there is a risk of ion suppression if a target protein is coincubated with multiple candidate ligands. These factors, along with the fairly labor-intensive nature, required operator skill, and limited throughput of most implementations, represent significant obstacles to the widespread adoption of native mass spectrometry-based ligand discovery. Here, we demonstrate the combination of flow-induced dispersion analysis with native mass spectrometry for screening of ligands for an E3 ligase and two kinases of pharmacological relevance. Importantly, this approach avoids ion suppression and formation of salt adducts without the need for offline desalting or buffer exchange, and each multiplexed measurement of a sample consisting of a target protein and a mixture of more than 20 candidate ligands took only a few minutes. Because the method is largely automated, this screening technology represents a potentially important step toward making native mass spectrometry a mainstream biophysical technique in drug discovery.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-05-05
DOI
https://doi.org/10.1021/acs.analchem.5c00696
Citations
4
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
3.03

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Native Flow-Induced Dispersion Analysis – Mass Spectrometry Enables Automated, Multiplexed Ligand Screening from Conventional, Nonvolatile Buffers

Stefan Knapp, Aylin Berwanger, Sebastian Mathea, Martin Empting et al.
4 citations
Analytical Chemistry
Mass Spectrometry Techniques and Applications
3.03
article

Native Flow-Induced Dispersion Analysis – Mass Spectrometry Enables Automated, Multiplexed Ligand Screening from Conventional, Nonvolatile Buffers

Stefan Knapp, Aylin Berwanger, Sebastian Mathea, Martin Empting, Edvaldo Vasconcelos Soares Maciel, Jonathan Eisert, Henrik Jensen, Frederik Lermyte, Verena Dederer
article en
4 citations

Abstract

Native electrospray ionization mass spectrometry has become an important method for the discovery and validation of noncovalent ligands for therapeutic targets. As a label-free method combining high sensitivity and chemical specificity, it is ideally suited for this application. However, the performance of the method is severely impacted by the presence of nonvolatile buffers and salts, and there is a risk of ion suppression if a target protein is coincubated with multiple candidate ligands. These factors, along with the fairly labor-intensive nature, required operator skill, and limited throughput of most implementations, represent significant obstacles to the widespread adoption of native mass spectrometry-based ligand discovery. Here, we demonstrate the combination of flow-induced dispersion analysis with native mass spectrometry for screening of ligands for an E3 ligase and two kinases of pharmacological relevance. Importantly, this approach avoids ion suppression and formation of salt adducts without the need for offline desalting or buffer exchange, and each multiplexed measurement of a sample consisting of a target protein and a mixture of more than 20 candidate ligands took only a few minutes. Because the method is largely automated, this screening technology represents a potentially important step toward making native mass spectrometry a mainstream biophysical technique in drug discovery.

Analytical ChemistryVol. 97(19)
Goethe University Frankfurt (DE), Technische Universität Darmstadt (DE), Biosyntia (Denmark) (DK), German Center for Infection Research (DE), Helmholtz Institute for Pharmaceutical Research Saarland (DE), Frankfurt Cancer Institute (DE), Saarland University (DE)
Boehringer Ingelheim, Bristol-Myers Squibb, Pfizer, Bayer, Alexander von Humboldt-Stiftung, Genome Canada, Takeda Foundation, Fonds der Chemischen Industrie, Deutsche Forschungsgemeinschaft, Hessisches Ministerium für Wissenschaft und Kunst, Deutsche Krebshilfe, Deutschen Konsortium für Translationale Krebsforschung, Genentech, Janssen Pharmaceuticals
Openalex Percentile: Top 9%
Mass Spectrometry Techniques and Applications
3.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.