Acoustic Characterization of AC Motor Using Sound Intensity in Non-Anechoic Laboratory Environments

<div class="section abstract"><div class="htmlview paragraph">Sound power is a commonly used metric to quantify acoustic sources like AC motor in electrified powertrain. Testing for sound power determination is often performed in an anechoic environment to create free-field conditions around the unit. To eliminate the influence of extraneous noise sources, the anechoic facilities must be further isolated from driver and absorber dynamometers. These dynamometers are needed for running the AC motors in the desired speed and load conditions.</div><div class="htmlview paragraph">For early detection of potential issues, it is advantageous to have the capability for engineers to conduct acoustic tests in standard laboratory environments. These may include non-acoustically treated rooms, presence of extraneous noise sources (e.g., driver and absorber dynos), etc. In such environments, sound intensity-based sound power determination methods could be utilized. The sound intensity-based approach is covered in ISO 9614 standard. The norm is to sweep an intensity probe on a sound source in constant speed condition to cover all the surfaces around the source. However, standing next to a high speed, high voltage electric motor to perform intensity probe sweep poses safety risks.</div><div class="htmlview paragraph">To counter this challenge, a different approach is applied using Pressure Velocity (p-u) intensity probe array around the test subject. In this alternative approach, the use of intensity probe array to calculate sound power of AC motor is discussed. Also detailed is how the measurements are validated to ensure they conform to ISO field indicators. The validation process included considerations such as size of the array, distance from the array and number of probes in the array.</div><div class="htmlview paragraph">The key advantage of this approach is the ability to perform speed sweeps on the motor in semi-reverberant acoustic environment, which could help in identifying potential issues early on in the development.</div></div>

Authors

Institutions

Publication Details

Journal
SAE technical papers on CD-ROM/SAE technical paper series
Published
2025-05-05
DOI
https://doi.org/10.4271/2025-01-0010
Primary Topic
Electric Motor Design and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Acoustic Characterization of AC Motor Using Sound Intensity in Non-Anechoic Laboratory Environments

Rajani Ippili, Aditya Kumar
SAE technical papers on CD-ROM/SAE technical paper series
Electric Motor Design and Analysis
article

Acoustic Characterization of AC Motor Using Sound Intensity in Non-Anechoic Laboratory Environments

Rajani Ippili, Aditya Kumar
article en

Abstract

<div class="section abstract"><div class="htmlview paragraph">Sound power is a commonly used metric to quantify acoustic sources like AC motor in electrified powertrain. Testing for sound power determination is often performed in an anechoic environment to create free-field conditions around the unit. To eliminate the influence of extraneous noise sources, the anechoic facilities must be further isolated from driver and absorber dynamometers. These dynamometers are needed for running the AC motors in the desired speed and load conditions.</div><div class="htmlview paragraph">For early detection of potential issues, it is advantageous to have the capability for engineers to conduct acoustic tests in standard laboratory environments. These may include non-acoustically treated rooms, presence of extraneous noise sources (e.g., driver and absorber dynos), etc. In such environments, sound intensity-based sound power determination methods could be utilized. The sound intensity-based approach is covered in ISO 9614 standard. The norm is to sweep an intensity probe on a sound source in constant speed condition to cover all the surfaces around the source. However, standing next to a high speed, high voltage electric motor to perform intensity probe sweep poses safety risks.</div><div class="htmlview paragraph">To counter this challenge, a different approach is applied using Pressure Velocity (p-u) intensity probe array around the test subject. In this alternative approach, the use of intensity probe array to calculate sound power of AC motor is discussed. Also detailed is how the measurements are validated to ensure they conform to ISO field indicators. The validation process included considerations such as size of the array, distance from the array and number of probes in the array.</div><div class="htmlview paragraph">The key advantage of this approach is the ability to perform speed sweeps on the motor in semi-reverberant acoustic environment, which could help in identifying potential issues early on in the development.</div></div>

SAE technical papers on CD-ROM/SAE technical paper seriesVol. 1
Siemens (Germany) (DE), Dana (United States) (US)
Openalex Percentile: Top 92%
Electric Motor Design and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies