New System for the Measurement of Sound-Insertion Loss on Small Samples: A Comparison with ASTM-E2611 and ASTM E90 Test Procedures

<div class="section abstract"><div class="htmlview paragraph">This article follows a companion article [<span class="xref">1</span>] presented at the SAE NVC 2021, in which a new system for the measurement on small samples of the normal-incidence Insertion Loss (IL) of multilayers used for the manufacturing of automotive sound package parts was first introduced. In addition to simplifying the evaluation of the sound-insulation of multi-layers used to produce sound-package components, the system aims at overcoming the limitations of the test procedure based on the ASTM E2611 standard.</div><div class="htmlview paragraph">In this article, the latter point is demonstrated by comparing the insertion loss results obtained with the new system with those obtained with the test procedure based on the ASTM E2611 standard on a few multilayers commonly used for the manufacturing of automotive sound package parts. Results indicate that the data obtained by means of the newly developed system are more meaningful, practically usable and less prone to edge-effects, compared to those obtained according to the ASTM E2611 test procedure.</div><div class="htmlview paragraph">In addition to this, the article compares also the results obtained by means of the new system with those obtained in a compact two-cabins facility commonly used for the evaluation of diffuse-field insertion loss following the ASTM E90 standard, a quantity customarily employed in the automotive industry for the assessment of the sound insulation of acoustic multilayers. Results indicate that the data obtained with the new system compare well with those obtained with the two-cabins facility, both quantitatively and qualitatively. This indicates that sound-insulation tests with the new system may be a valid alternative to much more resource-consuming tests in two-chamber facilities, in particular (but not only) when the sound insulation of moulded parts must be assessed.</div></div>

Authors

Institutions

Publication Details

Journal
SAE technical papers on CD-ROM/SAE technical paper series
Published
2025-05-05
DOI
https://doi.org/10.4271/2025-01-0116
Primary Topic
Acoustic Wave Phenomena Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

New System for the Measurement of Sound-Insertion Loss on Small Samples: A Comparison with ASTM-E2611 and ASTM E90 Test Procedures

Jan Hořák, Giulio Ruggeri, Claudio Bertolini
SAE technical papers on CD-ROM/SAE technical paper series
Acoustic Wave Phenomena Research
article

New System for the Measurement of Sound-Insertion Loss on Small Samples: A Comparison with ASTM-E2611 and ASTM E90 Test Procedures

Jan Hořák, Giulio Ruggeri, Claudio Bertolini
article en

Abstract

<div class="section abstract"><div class="htmlview paragraph">This article follows a companion article [<span class="xref">1</span>] presented at the SAE NVC 2021, in which a new system for the measurement on small samples of the normal-incidence Insertion Loss (IL) of multilayers used for the manufacturing of automotive sound package parts was first introduced. In addition to simplifying the evaluation of the sound-insulation of multi-layers used to produce sound-package components, the system aims at overcoming the limitations of the test procedure based on the ASTM E2611 standard.</div><div class="htmlview paragraph">In this article, the latter point is demonstrated by comparing the insertion loss results obtained with the new system with those obtained with the test procedure based on the ASTM E2611 standard on a few multilayers commonly used for the manufacturing of automotive sound package parts. Results indicate that the data obtained by means of the newly developed system are more meaningful, practically usable and less prone to edge-effects, compared to those obtained according to the ASTM E2611 test procedure.</div><div class="htmlview paragraph">In addition to this, the article compares also the results obtained by means of the new system with those obtained in a compact two-cabins facility commonly used for the evaluation of diffuse-field insertion loss following the ASTM E90 standard, a quantity customarily employed in the automotive industry for the assessment of the sound insulation of acoustic multilayers. Results indicate that the data obtained with the new system compare well with those obtained with the two-cabins facility, both quantitatively and qualitatively. This indicates that sound-insulation tests with the new system may be a valid alternative to much more resource-consuming tests in two-chamber facilities, in particular (but not only) when the sound insulation of moulded parts must be assessed.</div></div>

SAE technical papers on CD-ROM/SAE technical paper seriesVol. 1
Autoneum (Switzerland) (CH)
Openalex Percentile: Top 91%
Acoustic Wave Phenomena Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.