The role of transit-time flow measurement and epicardial ultrasound in coronary artery bypass surgery: application of clinical practice

Introduction: Coronary artery bypass grafting remains the most commonly performed procedure for coronary artery disease. Technological and surgical innovations, including off-pump and minimally invasive surgery, have reduced risks and shortened recovery time, but demand higher technical expertise. Moreover, modern medicine also requires higher safety standards, transit-time flow measurement and epicardial ultrasound are essential techniques used for quality assesment and identifying issue during coronary artery bypass grafting surgery. Objective: To evaluate the impact of transit-time flow measurement and epicardial ultrasound in patients undergoing coronary artery bypass grafting surgery. Methods: A retrospective analysis of patients who underwent coronary artery bypass grafting surgery with the use of transit-time flow measurement and epicardial ultrasound. Identify the rate of changes in the selection of anastomosis sites based on epicardial ultrasound, assess graft quality using transit-time flow measurement parameters, and identify the rate of required revisions. Evaluate the rate of in-hospital mortality and major morbidity. Results: From January 2021 to October 2024, 98 patients underwent coronary artery bypass grafting surgery with transit-time flow measurement and epicardial ultrasound at Military Hospital 175. Mean age was 61.9 years, with 24.8% female, and diabetes mellitus was 36.7%. Off-pump coronary artery bypass surgery was performed in 80.6% (n=79) of cases, minimally invasive direct coronary artery bypass in 9.2% (n=9), traditional on-pump coronary artery bypass surgery in 17.3% (n=17), and on-pump beating heart surgery in 2% (n=2). Surgical changes were made in 33.7% of patients (n=98), with 72.7% (24 out of 33) based on findings from transit-time flow measurement and/or epicardial ultrasound. Surgical changes were related to the aorta in 10.4%, to graft vessels in 2.6%, and coronary targets in 8.3%. The rate of change in the selection of anastomosis placement based on epicardial ultrasound is 10.8% (25/230).The rate of graft revision is 0.9%. The in-hospital mortality rate was 3.1%, cerebrovascular events in 2.0%, and no new myocardial infarctions were reported. Conclusion: Surgical changes related to the aorta, graft vessels, coronary targets, and anastomosis were performed in 33.7% of patients, contributing to low surgical mortality and severe complication rates. The combined use of transit-time flow measurement and epicardial ultrasound can enhance the quality, safety, and efficacy of coronary artery bypass grafting procedures and should be considered a standard for routine application.

Authors

Institutions

Publication Details

Journal
Tạp chí Phẫu thuật và Tim mạch và Lồng ngực Việt Nam
Published
2025-04-03
DOI
https://doi.org/10.47972/vjcts.v50i.1300
Primary Topic
Cardiac Imaging and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The role of transit-time flow measurement and epicardial ultrasound in coronary artery bypass surgery: application of clinical practice

Nguyễn Hoàng Định, David Nguyen, Dieu Hien Truong
Tạp chí Phẫu thuật và Tim mạch và Lồng ngực Việt Nam
Cardiac Imaging and Diagnostics
article

The role of transit-time flow measurement and epicardial ultrasound in coronary artery bypass surgery: application of clinical practice

Nguyễn Hoàng Định, David Nguyen, Dieu Hien Truong
article en

Abstract

Introduction: Coronary artery bypass grafting remains the most commonly performed procedure for coronary artery disease. Technological and surgical innovations, including off-pump and minimally invasive surgery, have reduced risks and shortened recovery time, but demand higher technical expertise. Moreover, modern medicine also requires higher safety standards, transit-time flow measurement and epicardial ultrasound are essential techniques used for quality assesment and identifying issue during coronary artery bypass grafting surgery. Objective: To evaluate the impact of transit-time flow measurement and epicardial ultrasound in patients undergoing coronary artery bypass grafting surgery. Methods: A retrospective analysis of patients who underwent coronary artery bypass grafting surgery with the use of transit-time flow measurement and epicardial ultrasound. Identify the rate of changes in the selection of anastomosis sites based on epicardial ultrasound, assess graft quality using transit-time flow measurement parameters, and identify the rate of required revisions. Evaluate the rate of in-hospital mortality and major morbidity. Results: From January 2021 to October 2024, 98 patients underwent coronary artery bypass grafting surgery with transit-time flow measurement and epicardial ultrasound at Military Hospital 175. Mean age was 61.9 years, with 24.8% female, and diabetes mellitus was 36.7%. Off-pump coronary artery bypass surgery was performed in 80.6% (n=79) of cases, minimally invasive direct coronary artery bypass in 9.2% (n=9), traditional on-pump coronary artery bypass surgery in 17.3% (n=17), and on-pump beating heart surgery in 2% (n=2). Surgical changes were made in 33.7% of patients (n=98), with 72.7% (24 out of 33) based on findings from transit-time flow measurement and/or epicardial ultrasound. Surgical changes were related to the aorta in 10.4%, to graft vessels in 2.6%, and coronary targets in 8.3%. The rate of change in the selection of anastomosis placement based on epicardial ultrasound is 10.8% (25/230).The rate of graft revision is 0.9%. The in-hospital mortality rate was 3.1%, cerebrovascular events in 2.0%, and no new myocardial infarctions were reported. Conclusion: Surgical changes related to the aorta, graft vessels, coronary targets, and anastomosis were performed in 33.7% of patients, contributing to low surgical mortality and severe complication rates. The combined use of transit-time flow measurement and epicardial ultrasound can enhance the quality, safety, and efficacy of coronary artery bypass grafting procedures and should be considered a standard for routine application.

Tạp chí Phẫu thuật và Tim mạch và Lồng ngực Việt NamVol. 50
Military Hospital (PK), University Medical Center HCMC (VN)
Openalex Percentile: Top 86%
Cardiac Imaging and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.