On the use of dynamic film to improve the thermal and solar performance of multiple glazing units. Preliminary testing and assessment

Transparent systems play a crucial role in modern buildings affecting energy performance, visual and thermal comfort and interrelation between external and indoor environments. Due to the highly daily and seasonal variations in outdoor conditions and indoor requirements, dynamic façades represent a viable solution for optimizing overall building performance. This paper explores the potential of moveable transparent/opaque films placed within the gap of double glazing units. A selection of transparent and opaque polyester films was screened, and the optical properties and thermal emissivity of the selected samples were measured using laboratory equipment compliant with relevant international standards. Depending on the films, the solar transmittance ranged from 0 % to 75 % while the solar reflectance varied from 7 % to 89 %; the emissivity values were within the 0.10–0.80 range. When applied to double glazing units, the thermal transmittance decreased by up to 1.2 W/m 2 K in conventional glazing systems and by up to 0.3 W/m 2 K in low emissivity glazing systems, respectively. The solar properties, namely the solar factor, of the assembled units were extremely scattered, depending on the characteristics of both the glazing unit and the film, as reported in the results. The numerical analyses carried out at building scale on a reference residential case study, demonstrate that this technology can achieve up to 8 % energy savings for space heating and over 80 % for space cooling, depending on the glazing unit characteristics, the activation strategy and the climatic conditions within the Italian context. • Screening of micro-metric films for glazing applications. • Films radiative properties' ranges: 0–75 % for solar transmittance, 7–89 % for solar reflectance, 0.07–0.78 for thermal emissivity. • Thermal transmittance of double-glazing units may decrease by up to 1.2 W/m 2 K. • Space heating and cooling use decrease by up to 8 % and 80 %, respectively.

Authors

Institutions

Publication Details

Journal
Energy Reports
Published
2025-05-05
DOI
https://doi.org/10.1016/j.egyr.2025.04.064
Citations
2
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On the use of dynamic film to improve the thermal and solar performance of multiple glazing units. Preliminary testing and assessment

Carlo Romeo, Stefano Agnoli, Michele Zinzi, Luca Papaiz
2 citations
Energy Reports
Building Energy and Comfort Optimization
2.01
article

On the use of dynamic film to improve the thermal and solar performance of multiple glazing units. Preliminary testing and assessment

Carlo Romeo, Stefano Agnoli, Michele Zinzi, Luca Papaiz
article en
2 citations

Abstract

Transparent systems play a crucial role in modern buildings affecting energy performance, visual and thermal comfort and interrelation between external and indoor environments. Due to the highly daily and seasonal variations in outdoor conditions and indoor requirements, dynamic façades represent a viable solution for optimizing overall building performance. This paper explores the potential of moveable transparent/opaque films placed within the gap of double glazing units. A selection of transparent and opaque polyester films was screened, and the optical properties and thermal emissivity of the selected samples were measured using laboratory equipment compliant with relevant international standards. Depending on the films, the solar transmittance ranged from 0 % to 75 % while the solar reflectance varied from 7 % to 89 %; the emissivity values were within the 0.10–0.80 range. When applied to double glazing units, the thermal transmittance decreased by up to 1.2 W/m 2 K in conventional glazing systems and by up to 0.3 W/m 2 K in low emissivity glazing systems, respectively. The solar properties, namely the solar factor, of the assembled units were extremely scattered, depending on the characteristics of both the glazing unit and the film, as reported in the results. The numerical analyses carried out at building scale on a reference residential case study, demonstrate that this technology can achieve up to 8 % energy savings for space heating and over 80 % for space cooling, depending on the glazing unit characteristics, the activation strategy and the climatic conditions within the Italian context. • Screening of micro-metric films for glazing applications. • Films radiative properties' ranges: 0–75 % for solar transmittance, 7–89 % for solar reflectance, 0.07–0.78 for thermal emissivity. • Thermal transmittance of double-glazing units may decrease by up to 1.2 W/m 2 K. • Space heating and cooling use decrease by up to 8 % and 80 %, respectively.

Energy ReportsVol. 13
National Agency for New Technologies, Energy and Sustainable Economic Development (IT), Pininfarina (Italy) (IT)
Affordable and clean energy
Openalex Percentile: Top 15%
Building Energy and Comfort Optimization
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.