High definition imaging in the Mega Amp Spherical Tokamak

An absolutely calibrated, visible imaging diagnostic has been deployed on the MAST spherical tokamak. Two sets of three-color channels are defined using a combination of stacked multi-cavity interference filters, color-glass filter, and a color-pixel sensor. The system is compact with a single viewing pupil, which facilitates unambiguous comparisons of measurements in 2D. The sensor has a 12-bit dynamic range, 50 μs to 10 ms integration time (with 100-200 Hz frame rate), and a wide field of view with 640 × 480 resolution. The center-wavelength and the spectral bandpass for all colors are maintained across the field of view as they are controlled in the optical telecentric domain. The design views a complete plasma cross section, which contains passive plasma-edge and active interior emissions: one of the two neutral beam emissions, plasma-impurity charge-exchange emissions from both equator neutral beams, and two colors of bremsstrahlung.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2025-05-01
DOI
https://doi.org/10.1063/5.0252851
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High definition imaging in the Mega Amp Spherical Tokamak

S. Henderson, N. J. Conway, Anita Patel
Review of Scientific Instruments
Magnetic confinement fusion research
article

High definition imaging in the Mega Amp Spherical Tokamak

S. Henderson, N. J. Conway, Anita Patel
article en

Abstract

An absolutely calibrated, visible imaging diagnostic has been deployed on the MAST spherical tokamak. Two sets of three-color channels are defined using a combination of stacked multi-cavity interference filters, color-glass filter, and a color-pixel sensor. The system is compact with a single viewing pupil, which facilitates unambiguous comparisons of measurements in 2D. The sensor has a 12-bit dynamic range, 50 μs to 10 ms integration time (with 100-200 Hz frame rate), and a wide field of view with 640 × 480 resolution. The center-wavelength and the spectral bandpass for all colors are maintained across the field of view as they are controlled in the optical telecentric domain. The design views a complete plasma cross section, which contains passive plasma-edge and active interior emissions: one of the two neutral beam emissions, plasma-impurity charge-exchange emissions from both equator neutral beams, and two colors of bremsstrahlung.

Review of Scientific InstrumentsVol. 96(5)
United Kingdom Atomic Energy Authority (GB)
Culham Centre for Fusion Energy, Engineering and Physical Sciences Research Council
Affordable and clean energy
Openalex Percentile: Top 95%
Magnetic confinement fusion research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.