Orbital Remodeling and 3-dimensional Printing in Delayed Orbital Floor Fracture Reconstructions

The mechanism and physiology of orbital cavity remodeling after orbital fractures is not well described. This poses a challenge in the delayed operative treatment of orbital floor fractures due to variations from expected anatomy and may risk injury to critical structures during exploration as well as misguided reconstruction, causing persistent ocular dystopia. We report a case where significant orbital remodeling caused unexpected challenges to orbital floor reconstruction, highlighting the need for further research in this field. A 23-year-old previously healthy man was treated conservatively for a left orbital floor fracture sustained during a rugby match. At a 4-month follow-up, the patient was found to have significant ocular dystopia with vertical diplopia and cosmetically significant enophthalmos. A discrepancy of 4 mm was noted on exophthalmometry. Intraoperatively, the neo-floor was found to have fully healed but with significant downsloping angulation and clinically appreciable depression. Furthermore, no fracture ledges were able to be used to guide the height of the titanium reconstruction plate, posing a significant challenge. Therefore, a 3-dimensional printed model of the orbit using a recent computed tomography scan was used to conform the plate to the required dimensions. The patient made a good recovery without ocular symptoms. Fracture remodeling of the orbital cavity is poorly described and may not be considered in the delayed treatment of orbital fractures. Further research to describe the mechanism and pattern of how this occurs is necessary. Computer-assisted design with 3-dimensional printing is a useful tool that can help overcome technical challenges in complex maxillofacial cases.

Authors

Institutions

Publication Details

Journal
Plastic & Reconstructive Surgery Global Open
Published
2025-05-01
DOI
https://doi.org/10.1097/gox.0000000000006772
Citations
1
Primary Topic
Facial Trauma and Fracture Management
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Orbital Remodeling and 3-dimensional Printing in Delayed Orbital Floor Fracture Reconstructions

Quan Ngo, Yewon Kim, Brandon He
1 citations
Plastic & Reconstructive Surgery Global Open
Facial Trauma and Fracture Management
2.01
article

Orbital Remodeling and 3-dimensional Printing in Delayed Orbital Floor Fracture Reconstructions

Quan Ngo, Yewon Kim, Brandon He
article en
1 citations

Abstract

The mechanism and physiology of orbital cavity remodeling after orbital fractures is not well described. This poses a challenge in the delayed operative treatment of orbital floor fractures due to variations from expected anatomy and may risk injury to critical structures during exploration as well as misguided reconstruction, causing persistent ocular dystopia. We report a case where significant orbital remodeling caused unexpected challenges to orbital floor reconstruction, highlighting the need for further research in this field. A 23-year-old previously healthy man was treated conservatively for a left orbital floor fracture sustained during a rugby match. At a 4-month follow-up, the patient was found to have significant ocular dystopia with vertical diplopia and cosmetically significant enophthalmos. A discrepancy of 4 mm was noted on exophthalmometry. Intraoperatively, the neo-floor was found to have fully healed but with significant downsloping angulation and clinically appreciable depression. Furthermore, no fracture ledges were able to be used to guide the height of the titanium reconstruction plate, posing a significant challenge. Therefore, a 3-dimensional printed model of the orbit using a recent computed tomography scan was used to conform the plate to the required dimensions. The patient made a good recovery without ocular symptoms. Fracture remodeling of the orbital cavity is poorly described and may not be considered in the delayed treatment of orbital fractures. Further research to describe the mechanism and pattern of how this occurs is necessary. Computer-assisted design with 3-dimensional printing is a useful tool that can help overcome technical challenges in complex maxillofacial cases.

Plastic & Reconstructive Surgery Global OpenVol. 13(5)
Liverpool Hospital (AU), UNSW Sydney (AU)
Sustainable cities and communities
Openalex Percentile: Top 16%
Facial Trauma and Fracture Management
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Orbital Remodeling and 3-dimensional Printing in Delayed Orbital Floor Fracture Reconstructions — Quan Ngo, Yewon Kim, et al. · Plastic & Reconstructive Surgery Global Open (2025) | TGRS Research Map | TGRS