Factorial design assisted electrochemical detection of cypermethrin using molecularly imprinted polyaniline

Abstract Cypermethrin (CYP), a widely used pyrethroid insecticide, poses significant risks to human health and aquatic ecosystems due to its extensive application. Despite the advantages of electrochemical sensors, such as simplicity, rapid response, and ease of use, the electrochemically inactive nature of CYP presents a major challenge for direct detection. In this study, a molecularly imprinted polyaniline (MIPANI)-based electrochemical sensor was developed for the sensitive detection of CYP using a label-based approach. A redox probe, potassium ferrocyanide/ferricyanide, was employed to generate signals based on the presence or absence of CYP at the sensor’s electroactive surface, enabling quantitative analysis from aqueous samples. Unlike previous studies relying on one-factor-at-a-time (OFAT) approaches, a two-level factorial design was applied to optimize key parameters. Statistical analysis (ANOVA, R 2 = 0.9956) confirmed the significant influence of these factors, ensuring a robust and reliable sensor performance. The total electrochemically active surface area analysis confirmed that MIP-eluted exhibited the highest active area, outperforming MIP-rebinded and non-imprinted polymer (NIP) forms. The sensor demonstrated a linear response from 0.01 to 0.5 μM, with a low detection limit (LOD) of 70 nM. Additionally, it exhibited good reproducibility and excellent selectivity against common interfering pesticides.

Authors

Institutions

Publication Details

Journal
Pure and Applied Chemistry
Published
2025-05-05
DOI
https://doi.org/10.1515/pac-2024-0354
Citations
1
Primary Topic
Electrochemical Analysis and Applications
Type
article
Field-Weighted Citation Impact
0.52

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Factorial design assisted electrochemical detection of cypermethrin using molecularly imprinted polyaniline

Ahmad Husaini Mohamed, Saliza Asman, Adrina Zulkifli, Siti Nor Atika Baharin et al.
1 citations
Pure and Applied Chemistry
Electrochemical Analysis and Applications
0.52
article

Factorial design assisted electrochemical detection of cypermethrin using molecularly imprinted polyaniline

Ahmad Husaini Mohamed, Saliza Asman, Adrina Zulkifli, Siti Nor Atika Baharin, Muggundha Raoov, Kavirajaa Pandian Sambasevam, Tilagam Marimuthu
article en
1 citations

Abstract

Abstract Cypermethrin (CYP), a widely used pyrethroid insecticide, poses significant risks to human health and aquatic ecosystems due to its extensive application. Despite the advantages of electrochemical sensors, such as simplicity, rapid response, and ease of use, the electrochemically inactive nature of CYP presents a major challenge for direct detection. In this study, a molecularly imprinted polyaniline (MIPANI)-based electrochemical sensor was developed for the sensitive detection of CYP using a label-based approach. A redox probe, potassium ferrocyanide/ferricyanide, was employed to generate signals based on the presence or absence of CYP at the sensor’s electroactive surface, enabling quantitative analysis from aqueous samples. Unlike previous studies relying on one-factor-at-a-time (OFAT) approaches, a two-level factorial design was applied to optimize key parameters. Statistical analysis (ANOVA, R 2 = 0.9956) confirmed the significant influence of these factors, ensuring a robust and reliable sensor performance. The total electrochemically active surface area analysis confirmed that MIP-eluted exhibited the highest active area, outperforming MIP-rebinded and non-imprinted polymer (NIP) forms. The sensor demonstrated a linear response from 0.01 to 0.5 μM, with a low detection limit (LOD) of 70 nM. Additionally, it exhibited good reproducibility and excellent selectivity against common interfering pesticides.

Pure and Applied ChemistryVol. 97(8)
University of Malaya (MY), Malaysia Theological Seminary (MY), Universiti Teknologi MARA (MY), Tun Hussein Onn University of Malaysia (MY)
Kurita Water and Environment Foundation
Openalex Percentile: Top 44%
Electrochemical Analysis and Applications
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.