Interpreting frequency evolution in ventricular fibrillation using embeddings and deep learning methods

Recently, the necessity for advanced tools to scrutinize ventricular fibrillation (VF) has been highlighted. Despite progress in the field, applying deep learning techniques and manifold interpretations in clinical settings remains underexplored. This study aims to evaluate the effectiveness of low-dimensional embeddings for distinguishing VF. We analyzed VF from three clinical conditions: patients during cardiopulmonary bypass, dogs administered with different drugs, and implantable cardioverter defibrillator devices with varying offset characteristics. We employed several algorithms, including uniform manifold approximation and projection embeddings, temporal convolutional networks, fully connected networks, and Kolmogorov–Arnold networks. Our experiments revealed that VF dynamics can be categorized based on frequency evolution, and the result can be interpreted based on clinical knowledge. However, each dataset has unique characteristics, leading to variations in the best-performing method. These differences may arise because some VF types are more easily identifiable. Our findings prove that longer signals differentiate VF types more clearly as the frequency evolution becomes clearer over extended periods. Across the same dataset, methods showed only slight differences in performance. Notably, for one dataset, two different drugs in dogs showed similar frequency patterns. For the rest of the datasets and methods, accuracy ranged between 0.68 and 0.86, precision ranged from 0.69 to 0.84, recall ranged from 0.68 to 0.84, and F1 scores ranged from 0.68 to 0.84. We conclude that low-dimensional embeddings are an effective method for characterizing VF types, and these methods can support ongoing research that aims to clarify the mechanisms of VF.

Authors

Institutions

Publication Details

Journal
Engineering Applications of Artificial Intelligence
Published
2025-05-05
DOI
https://doi.org/10.1016/j.engappai.2025.110822
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Interpreting frequency evolution in ventricular fibrillation using embeddings and deep learning methods

José Luis Rojo‐Álvarez, Francisco-Manuel Melgarejo-Meseguer, Juan José Sánchez Muñoz, Luis Bote-Curiel et al.
Engineering Applications of Artificial Intelligence
ECG Monitoring and Analysis
article

Interpreting frequency evolution in ventricular fibrillation using embeddings and deep learning methods

José Luis Rojo‐Álvarez, Francisco-Manuel Melgarejo-Meseguer, Juan José Sánchez Muñoz, Luis Bote-Curiel, Francisco-Javier Gimeno-Blanes, Antonio Gil-Izquierdo, Dafne Lozano-Paredes
article en

Abstract

Recently, the necessity for advanced tools to scrutinize ventricular fibrillation (VF) has been highlighted. Despite progress in the field, applying deep learning techniques and manifold interpretations in clinical settings remains underexplored. This study aims to evaluate the effectiveness of low-dimensional embeddings for distinguishing VF. We analyzed VF from three clinical conditions: patients during cardiopulmonary bypass, dogs administered with different drugs, and implantable cardioverter defibrillator devices with varying offset characteristics. We employed several algorithms, including uniform manifold approximation and projection embeddings, temporal convolutional networks, fully connected networks, and Kolmogorov–Arnold networks. Our experiments revealed that VF dynamics can be categorized based on frequency evolution, and the result can be interpreted based on clinical knowledge. However, each dataset has unique characteristics, leading to variations in the best-performing method. These differences may arise because some VF types are more easily identifiable. Our findings prove that longer signals differentiate VF types more clearly as the frequency evolution becomes clearer over extended periods. Across the same dataset, methods showed only slight differences in performance. Notably, for one dataset, two different drugs in dogs showed similar frequency patterns. For the rest of the datasets and methods, accuracy ranged between 0.68 and 0.86, precision ranged from 0.69 to 0.84, recall ranged from 0.68 to 0.84, and F1 scores ranged from 0.68 to 0.84. We conclude that low-dimensional embeddings are an effective method for characterizing VF types, and these methods can support ongoing research that aims to clarify the mechanisms of VF.

Engineering Applications of Artificial IntelligenceVol. 154
Universitat de Miguel Hernández d'Elx (ES), Universidad Rey Juan Carlos (ES), Hospital Universitario Virgen de la Arrixaca (ES)
Universidad Rey Juan Carlos, Agencia Estatal de Investigación
Quality Education
Openalex Percentile: Top 83%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.