A Two-Segment Continuum Robot with Piecewise Stiffness for Tracheal Intubation and Active Decoupling

This study presents a two-segment continuum robot with piecewise stiffness, designed to enhance the precision, adaptability, and safety of tracheal intubation procedures. The robot employs a continuum manipulator (CM) as its end-effector, featuring a proximal segment (PS) with an aluminum alloy interlocking joint, which provides high axial stiffness for stable insertion, and a distal segment (DS) with a micro-nano resin-based notched structure, offering increased flexibility and compliance to navigate complex anatomical structures such as the epiglottis and vocal cords, thereby reducing airway trauma. To describe the motion behavior of the robot, a piecewise variable curvature kinematic model is developed, capturing the deformation characteristics of each segment under actuation. Furthermore, a piecewise stiffness analysis is conducted to determine the axial and bending stiffness of each segment, ensuring an appropriate balance between stability and flexibility. To enhance control precision, an active tendon-driven decoupling control strategy is introduced, effectively minimizing the interaction forces between flexible segments and improving end-effector maneuverability. The results demonstrate that the proposed design significantly improves the adaptability of the tracheal intubation robot, ensuring controlled insertion while reducing the risk of excessive force on the airway walls. This study provides theoretical and technical insights into the mechanical design and control strategies of continuum robots, contributing to the safety and efficiency of tracheal intubation.

Authors

Institutions

Publication Details

Journal
Actuators
Published
2025-05-05
DOI
https://doi.org/10.3390/act14050228
Primary Topic
Soft Robotics and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Two-Segment Continuum Robot with Piecewise Stiffness for Tracheal Intubation and Active Decoupling

Qiqi Pan, Hongbo Wang, Junjie Tian, Lingfeng Sang et al.
Actuators
Soft Robotics and Applications
article

A Two-Segment Continuum Robot with Piecewise Stiffness for Tracheal Intubation and Active Decoupling

Qiqi Pan, Hongbo Wang, Junjie Tian, Lingfeng Sang, Wenxian Li, Yuan Han, Yu Tian, Jianhao Tang
article en

Abstract

This study presents a two-segment continuum robot with piecewise stiffness, designed to enhance the precision, adaptability, and safety of tracheal intubation procedures. The robot employs a continuum manipulator (CM) as its end-effector, featuring a proximal segment (PS) with an aluminum alloy interlocking joint, which provides high axial stiffness for stable insertion, and a distal segment (DS) with a micro-nano resin-based notched structure, offering increased flexibility and compliance to navigate complex anatomical structures such as the epiglottis and vocal cords, thereby reducing airway trauma. To describe the motion behavior of the robot, a piecewise variable curvature kinematic model is developed, capturing the deformation characteristics of each segment under actuation. Furthermore, a piecewise stiffness analysis is conducted to determine the axial and bending stiffness of each segment, ensuring an appropriate balance between stability and flexibility. To enhance control precision, an active tendon-driven decoupling control strategy is introduced, effectively minimizing the interaction forces between flexible segments and improving end-effector maneuverability. The results demonstrate that the proposed design significantly improves the adaptability of the tracheal intubation robot, ensuring controlled insertion while reducing the risk of excessive force on the airway walls. This study provides theoretical and technical insights into the mechanical design and control strategies of continuum robots, contributing to the safety and efficiency of tracheal intubation.

ActuatorsVol. 14(5)
Fudan University (CN), Yanshan University (CN), Eye & ENT Hospital of Fudan University (CN), Ningbo Polytechnic (CN)
China Postdoctoral Science Foundation, National Key Research and Development Program of China
Openalex Percentile: Top 91%
Soft Robotics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.