Comparative Analysis of Bladder Volume Consistency Using Portable Ultrasound Scanners and Biofeedback in Radiotherapy for Pelvic Tumors

PurposeTo evaluate the accuracy of two bladder scanners (BS) in measuring bladder volume (BV) during radiotherapy (RT), and explore the influence of two bladder filling methods and patients' subjective urinary sensation on the consistency of BV.MethodsForty-two patients with pelvic tumors were divided into two groups: Group A (20 patients) and Group B (22 patients). Before the planning CT and each treatment session, all patients drank 500 mL of water after emptying their bladder and rectum. Group A waited for patients to provide feedback on urination, while Group B waited for 1 h. Subsequently, three consecutive measurements using two BSs were performed. The average volumes measured by the BS Padscan HD5 and Padscan HDW1 were recorded as BSHD5-v and BSHDW1-v, respectively. The differences between BSHD5-v, BSHDW1-v, and the BV obtained from planning CT (CT-v) or cone beam CT (CBCT) (CBCT-v) were assessed. The consistency between CBCT-v and CT-v in two patient groups was calculated. Urinary sensation score BV (V<sub>SC</sub>) was determined by the patient's urge to urinate score and CT-v.ResultsThe average CT-v or CBCT-v was 280 mL (range 78-710 mL, SD = 119 mL). BSHD5-v had an average of 271 mL (range 61-611 mL, SD = 115 mL), with a significant correlation with CT-v or CBCT-v (R = 0.89, p < 0.001). BSHDW1-v averaged 267 mL (range 92-634 mL, SD = 77 mL), positively correlated with CT-v or CBCT-v (R = 0.70, p < 0.001). Group A's CBCT-v proportions within ±20%, ± 30%, and ±50% of CT-v were 51.20%, 66.90%, and 91.90%, respectively, contrasting with Group B's 26.2%, 41.1%, and 67.7%. V<sub>SC</sub> exhibited a positive association with CBCT-v (R = 0.59, p < 0.001).ConclusionsConsistent and reproducible bladder volume was obtained by using Padscan HD5 and Padscan HDW1. The Padscan HD5 demonstrated greater consistency and accuracy. Furthermore, the urinary feedback method has a more consistent bladder volume than the fixed-time method.

Authors

Institutions

Publication Details

Journal
Technology in Cancer Research & Treatment
Published
2025-05-05
DOI
https://doi.org/10.1177/15330338251333645
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Analysis of Bladder Volume Consistency Using Portable Ultrasound Scanners and Biofeedback in Radiotherapy for Pelvic Tumors

Zhonghua Deng, Lu Zeng, Haitao Wang, Quan Zhong et al.
Technology in Cancer Research & Treatment
Advanced Radiotherapy Techniques
article

Comparative Analysis of Bladder Volume Consistency Using Portable Ultrasound Scanners and Biofeedback in Radiotherapy for Pelvic Tumors

Zhonghua Deng, Lu Zeng, Haitao Wang, Quan Zhong, Renming Zhong
article en

Abstract

PurposeTo evaluate the accuracy of two bladder scanners (BS) in measuring bladder volume (BV) during radiotherapy (RT), and explore the influence of two bladder filling methods and patients' subjective urinary sensation on the consistency of BV.MethodsForty-two patients with pelvic tumors were divided into two groups: Group A (20 patients) and Group B (22 patients). Before the planning CT and each treatment session, all patients drank 500 mL of water after emptying their bladder and rectum. Group A waited for patients to provide feedback on urination, while Group B waited for 1 h. Subsequently, three consecutive measurements using two BSs were performed. The average volumes measured by the BS Padscan HD5 and Padscan HDW1 were recorded as BSHD5-v and BSHDW1-v, respectively. The differences between BSHD5-v, BSHDW1-v, and the BV obtained from planning CT (CT-v) or cone beam CT (CBCT) (CBCT-v) were assessed. The consistency between CBCT-v and CT-v in two patient groups was calculated. Urinary sensation score BV (V<sub>SC</sub>) was determined by the patient's urge to urinate score and CT-v.ResultsThe average CT-v or CBCT-v was 280 mL (range 78-710 mL, SD = 119 mL). BSHD5-v had an average of 271 mL (range 61-611 mL, SD = 115 mL), with a significant correlation with CT-v or CBCT-v (R = 0.89, p < 0.001). BSHDW1-v averaged 267 mL (range 92-634 mL, SD = 77 mL), positively correlated with CT-v or CBCT-v (R = 0.70, p < 0.001). Group A's CBCT-v proportions within ±20%, ± 30%, and ±50% of CT-v were 51.20%, 66.90%, and 91.90%, respectively, contrasting with Group B's 26.2%, 41.1%, and 67.7%. V<sub>SC</sub> exhibited a positive association with CBCT-v (R = 0.59, p < 0.001).ConclusionsConsistent and reproducible bladder volume was obtained by using Padscan HD5 and Padscan HDW1. The Padscan HD5 demonstrated greater consistency and accuracy. Furthermore, the urinary feedback method has a more consistent bladder volume than the fixed-time method.

Technology in Cancer Research & TreatmentVol. 24
Sichuan University (CN), West China Hospital of Sichuan University (CN)
Openalex Percentile: Top 89%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.