The Wire Twisting/Locking Technique to Facilitate Precise PDA Stent Delivery in Neonates with Ductal-Dependent Pulmonary Blood Flow

Patent ductus arteriosus (PDA) stenting is an established alternative to systemic-to-pulmonary artery shunts for neonates with ductal-dependent pulmonary blood flow, offering a less invasive approach. However, the procedure remains technically challenging and prone to complications. We evaluated the wire twisting/locking technique to improve precision and safety during PDA stenting. This retrospective study, approved by the UC San Diego Institutional Review Board, analyzed the application of the wire twisting/locking technique for PDA stenting between Jan 2021 and Dec 2024. Data were extracted from electronic medical records, including patient demographics, diagnoses, procedural details, and outcomes. The wire twisting/locking technique was applied in 18 PDA stenting procedures performed on 11 patients with complex cyanotic congenital heart disease. The procedures included initial PDA stenting (n = 10) and PDA stent re-interventions (n = 8), comprising four balloon dilations and four stent placements. The median age of initial stent replacement was 9 days (IQR: 8-90), and the median weight was 3.88 kg (IQR: 3.17-6.05). Access sites included carotid (n = 10), femoral (n = 4), axillary (n = 2), and umbilical arteries (n = 2). The median stent diameter was 2.05 mm (IQR: 1.5-2.4), and the median stent length was 24.35 mm (IQR: 22-30 mm). The median procedure time was 91 min (IQR: 62-130) and a median radiation dose of 154.73 Gycm<sup>2</sup>. All procedures were successful, with no vascular or pulmonary complications. Median discharge oxygen saturation was 85% (IQR: 82-89). The wire twisting/locking technique represents a promising modification for PDA stenting. Utilizing a dynamic soft wire and opting for a single long stent simplifies stent placement and minimizes procedural complications.

Authors

Institutions

Publication Details

Journal
Pediatric Cardiology
Published
2025-05-05
DOI
https://doi.org/10.1007/s00246-025-03852-2
Citations
3
Primary Topic
Congenital Heart Disease Studies
Type
article
Field-Weighted Citation Impact
4.06
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Wire Twisting/Locking Technique to Facilitate Precise PDA Stent Delivery in Neonates with Ductal-Dependent Pulmonary Blood Flow

Justin Ryan, Laith Alshawabkeh, Howaida El‐Said, Brent M. Gordon et al.
3 citations
Pediatric Cardiology
Congenital Heart Disease Studies
4.06
article

The Wire Twisting/Locking Technique to Facilitate Precise PDA Stent Delivery in Neonates with Ductal-Dependent Pulmonary Blood Flow

Justin Ryan, Laith Alshawabkeh, Howaida El‐Said, Brent M. Gordon, Marjan Hesari, Mercy Ng'eno, Clinton Fulk
article en
3 citations

Abstract

Patent ductus arteriosus (PDA) stenting is an established alternative to systemic-to-pulmonary artery shunts for neonates with ductal-dependent pulmonary blood flow, offering a less invasive approach. However, the procedure remains technically challenging and prone to complications. We evaluated the wire twisting/locking technique to improve precision and safety during PDA stenting. This retrospective study, approved by the UC San Diego Institutional Review Board, analyzed the application of the wire twisting/locking technique for PDA stenting between Jan 2021 and Dec 2024. Data were extracted from electronic medical records, including patient demographics, diagnoses, procedural details, and outcomes. The wire twisting/locking technique was applied in 18 PDA stenting procedures performed on 11 patients with complex cyanotic congenital heart disease. The procedures included initial PDA stenting (n = 10) and PDA stent re-interventions (n = 8), comprising four balloon dilations and four stent placements. The median age of initial stent replacement was 9 days (IQR: 8-90), and the median weight was 3.88 kg (IQR: 3.17-6.05). Access sites included carotid (n = 10), femoral (n = 4), axillary (n = 2), and umbilical arteries (n = 2). The median stent diameter was 2.05 mm (IQR: 1.5-2.4), and the median stent length was 24.35 mm (IQR: 22-30 mm). The median procedure time was 91 min (IQR: 62-130) and a median radiation dose of 154.73 Gycm<sup>2</sup>. All procedures were successful, with no vascular or pulmonary complications. Median discharge oxygen saturation was 85% (IQR: 82-89). The wire twisting/locking technique represents a promising modification for PDA stenting. Utilizing a dynamic soft wire and opting for a single long stent simplifies stent placement and minimizes procedural complications.

Pediatric Cardiology
UC San Diego Health System (US), University of California San Diego (US), Neurological Surgery (US)
Good health and well-being
Openalex Percentile: Top 7%
Congenital Heart Disease Studies
4.06
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.