Strain shielding effect analysis of solid and porous Ti-6Al-4V alloy implanted femur bone using finite element analysis

In the proposed work, strain shielding effect analysis of solid and porous Ti-6Al-4V alloy implanted femur bone using finite element analysis is carried out. Strain shielding is a significant concern during total hip arthroplasty (THA) since it reduces bone growth and results in aseptic implant loosening due to the mismatch of femur and implant characteristics. The study examined solid and porous implanted femur bone under three loading conditions: standing, walking and stair climbing. The results show that strains on bone due to porous implants as compared to solid implants have been increased by 31, 24.3% and reduced by 12.18% for standing, walking, and stair climbing human activities, respectively. The findings show that porous implants promote bone growth and reduce aseptic implant loosening by lowering the strain and stress shielding effect.

Authors

Institutions

Publication Details

Journal
Journal of Medical Engineering & Technology
Published
2025-05-03
DOI
https://doi.org/10.1080/03091902.2025.2498748
Citations
1
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Strain shielding effect analysis of solid and porous Ti-6Al-4V alloy implanted femur bone using finite element analysis

Kailash Jha, Avinash M. Dongare, Sita Ram Modi
1 citations
Journal of Medical Engineering & Technology
Orthopaedic implants and arthroplasty
2.01
article

Strain shielding effect analysis of solid and porous Ti-6Al-4V alloy implanted femur bone using finite element analysis

Kailash Jha, Avinash M. Dongare, Sita Ram Modi
article en
1 citations

Abstract

In the proposed work, strain shielding effect analysis of solid and porous Ti-6Al-4V alloy implanted femur bone using finite element analysis is carried out. Strain shielding is a significant concern during total hip arthroplasty (THA) since it reduces bone growth and results in aseptic implant loosening due to the mismatch of femur and implant characteristics. The study examined solid and porous implanted femur bone under three loading conditions: standing, walking and stair climbing. The results show that strains on bone due to porous implants as compared to solid implants have been increased by 31, 24.3% and reduced by 12.18% for standing, walking, and stair climbing human activities, respectively. The findings show that porous implants promote bone growth and reduce aseptic implant loosening by lowering the strain and stress shielding effect.

Journal of Medical Engineering & TechnologyVol. 49(7)
Indian Institute of Technology Dhanbad (IN)
Openalex Percentile: Top 16%
Orthopaedic implants and arthroplasty
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.