ANALISIS SUSUT NON TEKNIS BERDASARKAN <i>LOAD PROFILE </i>DAN JAM NYALA PADA PELANGGAN AMR (<i>AUTOMATIC METR READING</i>) PT PLN (PERSERO) UP3 BIMA

Technical and non-technical losses occurs when PLN distributes electricity from generators to customers. To reduce this loss, namely by grouping based on running hours and monitoring the customer's Load Profile parameters. Analysis of research is needed to reduce non-technical losses, especially for large power customers who use the AMR system, such as 189 UP3 Bima customers. In this research, 2 customers experienced a decrease in operating hours exceeding 100 hours, with indications of measurement anomalies in these customers. After normalizing the system, there was uncollected electricity usage from 2 customers totaling 120,457.43 kWh which had not been paid for. PLN UP3 Bima managed to reduce the shrinkage rate by 16% of the total non-technical shrinkage in June 2024 with a total of 749,686 kWh. Keywords: Electricity distribution, kWh meter, non-technical losses. ABSTRAK Susut teknis dan non teknis terjadi saat PLN mendistribusi tenaga listrik dari pembangkit hingga ke pelanggan. Untuk mengurangi susut tersebut yaitu dengan cara mengelompokkan berdasarkan jam nyala serta memantau parameter Load Profile pelanggan tersebut. Dibutuhkan suatu analisa atau penelitian, untuk menekan susut non teknis terutama pada pelanggan berdaya besar yang menggunakan sistem AMR, seperti pada pelanggan UP3 Bima sebanyak 189 pelanggan. Pada penelitian ini ada 2 pelanggan yang mengalami penurunan jam nyala melebihi 100 jam, dengan indikasi adanya anomali pengukuran di pelanggan tersebut. Setelah dilakukan penormalan sistem terdapat pemakaian tenaga listrik belum tertagih dari 2 pelanggan total sebesar 120.457,43 kWh yang belum terbayar. PLN UP3 Bima berhasil menekan angka susut sebesar 16% dari total susut nonteknis bulan Juni 2024 dengan jumlah 749.686 kWh.

Authors

Institutions

Publication Details

Journal
eLEKTRIKA
Published
2025-05-04
DOI
https://doi.org/10.26623/elektrika.v17i1.11498
Primary Topic
Computer Science and Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ANALISIS SUSUT NON TEKNIS BERDASARKAN LOAD PROFILE DAN JAM NYALA PADA PELANGGAN AMR (AUTOMATIC METR READING) PT PLN (PERSERO) UP3 BIMA

Anggi Rachmawati, Dedi Nugroho
eLEKTRIKA
Computer Science and Engineering
article

ANALISIS SUSUT NON TEKNIS BERDASARKAN LOAD PROFILE DAN JAM NYALA PADA PELANGGAN AMR (AUTOMATIC METR READING) PT PLN (PERSERO) UP3 BIMA

Anggi Rachmawati, Dedi Nugroho
article en

Abstract

Technical and non-technical losses occurs when PLN distributes electricity from generators to customers. To reduce this loss, namely by grouping based on running hours and monitoring the customer's Load Profile parameters. Analysis of research is needed to reduce non-technical losses, especially for large power customers who use the AMR system, such as 189 UP3 Bima customers. In this research, 2 customers experienced a decrease in operating hours exceeding 100 hours, with indications of measurement anomalies in these customers. After normalizing the system, there was uncollected electricity usage from 2 customers totaling 120,457.43 kWh which had not been paid for. PLN UP3 Bima managed to reduce the shrinkage rate by 16% of the total non-technical shrinkage in June 2024 with a total of 749,686 kWh. Keywords: Electricity distribution, kWh meter, non-technical losses. ABSTRAK Susut teknis dan non teknis terjadi saat PLN mendistribusi tenaga listrik dari pembangkit hingga ke pelanggan. Untuk mengurangi susut tersebut yaitu dengan cara mengelompokkan berdasarkan jam nyala serta memantau parameter Load Profile pelanggan tersebut. Dibutuhkan suatu analisa atau penelitian, untuk menekan susut non teknis terutama pada pelanggan berdaya besar yang menggunakan sistem AMR, seperti pada pelanggan UP3 Bima sebanyak 189 pelanggan. Pada penelitian ini ada 2 pelanggan yang mengalami penurunan jam nyala melebihi 100 jam, dengan indikasi adanya anomali pengukuran di pelanggan tersebut. Setelah dilakukan penormalan sistem terdapat pemakaian tenaga listrik belum tertagih dari 2 pelanggan total sebesar 120.457,43 kWh yang belum terbayar. PLN UP3 Bima berhasil menekan angka susut sebesar 16% dari total susut nonteknis bulan Juni 2024 dengan jumlah 749.686 kWh.

eLEKTRIKAVol. 17(1)
Sultan Agung Islamic University (ID)
Openalex Percentile: Top 96%
Computer Science and Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

ANALISIS SUSUT NON TEKNIS BERDASARKAN <i>LOAD PROFILE </i>DAN JAM NYALA PADA PELANGGAN AMR (<i>AUTOMATIC METR READING</i>) PT PLN (PERSERO) UP3 BIMA — Anggi Rachmawati, Dedi Nugroho · eLEKTRIKA (2025) | TGRS Research Map | TGRS