Highly Sensitive Titanium-Based MXene-Reduced Graphene Oxide Composite for Efficient Electrochemical Detection of Cadmium and Copper Ions in Water

An electrochemically active and promising binary composite that is made up of titanium-based MXene (Ti3C2Tx) and rGO is developed to simultaneously detect the Cd2+ and Cu2+, in water. XRD, FTIR, Raman, XPS, FESEM, elemental mapping, and EDX analysis affirmed the successful formation of the Ti3C2Tx-rGO composite. The produced Ti3C2Tx-rGO electrode exhibited a homogeneous rGO sheet covering the Ti3C2Tx MXene plates with all the detailed Ti2p, C1s, and O1s XPS peaks. The high-performance Ti3C2Tx-rGO composite was successfully tested for the Cd2+ and Cu2+ ions via differential pulse voltammetry (DPV), altering the pH, concentration, and the real water sample’s quality. The electrochemical performances revealed that the proposed Ti3C2Tx-rGO composite depicted excellent detection and quantification limits (LOD and LOQ) for both Cd2+ (LOD = 0.31 nM, LOQ = 1.02 nM) and Cu2+ (LOD = 0.18 nM, LOQ = 0.62 nM) ions, where the result is highly comparable with the reported literature. The Ti3C2Tx-rGO was proven highly sensitive towards Cd2+ (0.345 μMμA−1) and Cu2+ (0.575 μMμA−1) with great repeatability and reproducibility properties. The Ti3C2Tx-rGO electrode also exhibited excellent stability over four weeks with a retention of 97.86% and 98.01% for Cd2+ and Cu2+, respectively. This simple modification of Ti3C2Tx with rGO can potentially be advantageous in the development of highly sensitive electrochemical sensors for the simultaneous detection of heavy metal ions.

Authors

Institutions

Publication Details

Journal
Journal of Composites Science
Published
2025-05-04
DOI
https://doi.org/10.3390/jcs9050232
Citations
6
Primary Topic
Electrochemical Analysis and Applications
Type
article
Field-Weighted Citation Impact
3.09
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Highly Sensitive Titanium-Based MXene-Reduced Graphene Oxide Composite for Efficient Electrochemical Detection of Cadmium and Copper Ions in Water

Rosiah Rohani, Yusran Sulaiman, Ebrahim Mahmoudi, Siti Fatimah Abd Rahman et al.
6 citations
Journal of Composites Science
Electrochemical Analysis and Applications
3.09
article

Highly Sensitive Titanium-Based MXene-Reduced Graphene Oxide Composite for Efficient Electrochemical Detection of Cadmium and Copper Ions in Water

Rosiah Rohani, Yusran Sulaiman, Ebrahim Mahmoudi, Siti Fatimah Abd Rahman, Dharshini Mohanadas
article en
6 citations

Abstract

An electrochemically active and promising binary composite that is made up of titanium-based MXene (Ti3C2Tx) and rGO is developed to simultaneously detect the Cd2+ and Cu2+, in water. XRD, FTIR, Raman, XPS, FESEM, elemental mapping, and EDX analysis affirmed the successful formation of the Ti3C2Tx-rGO composite. The produced Ti3C2Tx-rGO electrode exhibited a homogeneous rGO sheet covering the Ti3C2Tx MXene plates with all the detailed Ti2p, C1s, and O1s XPS peaks. The high-performance Ti3C2Tx-rGO composite was successfully tested for the Cd2+ and Cu2+ ions via differential pulse voltammetry (DPV), altering the pH, concentration, and the real water sample’s quality. The electrochemical performances revealed that the proposed Ti3C2Tx-rGO composite depicted excellent detection and quantification limits (LOD and LOQ) for both Cd2+ (LOD = 0.31 nM, LOQ = 1.02 nM) and Cu2+ (LOD = 0.18 nM, LOQ = 0.62 nM) ions, where the result is highly comparable with the reported literature. The Ti3C2Tx-rGO was proven highly sensitive towards Cd2+ (0.345 μMμA−1) and Cu2+ (0.575 μMμA−1) with great repeatability and reproducibility properties. The Ti3C2Tx-rGO electrode also exhibited excellent stability over four weeks with a retention of 97.86% and 98.01% for Cd2+ and Cu2+, respectively. This simple modification of Ti3C2Tx with rGO can potentially be advantageous in the development of highly sensitive electrochemical sensors for the simultaneous detection of heavy metal ions.

Journal of Composites ScienceVol. 9(5)
Universiti Putra Malaysia (MY), National University of Malaysia (MY)
Openalex Percentile: Top 9%
Electrochemical Analysis and Applications
3.09
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.