Investigation of performance characteristics of blended mineral oil and ester oil for transformer application

Abstract A transformer is one of the most important high voltage (HV) power apparatus in any electrical system. In transformers, liquid insulation, primarily mineral oil, is used in bulk. It acts as an insulation and cooling medium in the transformer. Therefore, it plays an important role in the safe and reliable operation of the transformer. It is understood from several studies that because of the shortage of petroleum oil and its non-environment-friendly nature, scientists, engineers, and researchers are concentrating their studies on synthetic oil, natural ester oil, so that they can replace mineral oil successfully. Studies related to the characterization of different types of natural ester oil are made for their superiority over mineral oil. However, very few studies have been conducted on different combinations of mineral oil (MO) with natural ester oil, such as coconut oil (CO) and rice bran oil (RO), as an alternative insulation. In this paper, a study has been made on different combinations of MO with CO and RO for their performance characteristic studies like breakdown voltage (BDV), flash point, DC resistivity, and tan delta on the lines of International Electrotechnical Commission (IEC) and American Society for Testing Materials (ASTM) standards. It is observed from the studies that different combinations of MO with CO and RO enhanced its BDV, which is the prime electrical property for studying the dielectric strength of any insulation. However, blended RO with MO has balanced properties in terms of dielectric strength, flash point, and DC resistivity compared to all other virgin oil and blended oils. It is also less toxic compared to the mineral oil. Therefore, blended rice bran oil with mineral oil may be considered an alternative to traditional mineral oil as it is cost-effective and less toxic. Therefore, it may be an efficient alternative to insulating oil for the transformer industries.

Authors

Institutions

Publication Details

Journal
International Journal of Emerging Electric Power Systems
Published
2025-05-04
DOI
https://doi.org/10.1515/ijeeps-2024-0333
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of performance characteristics of blended mineral oil and ester oil for transformer application

Daniel Jasper, Nirmal Kumar Roy, Sujit Khandai
International Journal of Emerging Electric Power Systems
Power Transformer Diagnostics and Insulation
article

Investigation of performance characteristics of blended mineral oil and ester oil for transformer application

Daniel Jasper, Nirmal Kumar Roy, Sujit Khandai
article en

Abstract

Abstract A transformer is one of the most important high voltage (HV) power apparatus in any electrical system. In transformers, liquid insulation, primarily mineral oil, is used in bulk. It acts as an insulation and cooling medium in the transformer. Therefore, it plays an important role in the safe and reliable operation of the transformer. It is understood from several studies that because of the shortage of petroleum oil and its non-environment-friendly nature, scientists, engineers, and researchers are concentrating their studies on synthetic oil, natural ester oil, so that they can replace mineral oil successfully. Studies related to the characterization of different types of natural ester oil are made for their superiority over mineral oil. However, very few studies have been conducted on different combinations of mineral oil (MO) with natural ester oil, such as coconut oil (CO) and rice bran oil (RO), as an alternative insulation. In this paper, a study has been made on different combinations of MO with CO and RO for their performance characteristic studies like breakdown voltage (BDV), flash point, DC resistivity, and tan delta on the lines of International Electrotechnical Commission (IEC) and American Society for Testing Materials (ASTM) standards. It is observed from the studies that different combinations of MO with CO and RO enhanced its BDV, which is the prime electrical property for studying the dielectric strength of any insulation. However, blended RO with MO has balanced properties in terms of dielectric strength, flash point, and DC resistivity compared to all other virgin oil and blended oils. It is also less toxic compared to the mineral oil. Therefore, blended rice bran oil with mineral oil may be considered an alternative to traditional mineral oil as it is cost-effective and less toxic. Therefore, it may be an efficient alternative to insulating oil for the transformer industries.

International Journal of Emerging Electric Power SystemsVol. 27(1)
National Institute of Technology Durgapur (IN)
Openalex Percentile: Top 92%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.