Experimental and modeling study of the current-potential behavior of an acid-base flow battery. Electrical performance determination as function of the number of single cell unit in stack

This work presents an experimental and modeling study of the current-potential behavior of an acid-base flow battery (AB-FB) by means of charge and discharge polarization curves in steady-state as function of the number of single cell units (SCUs) stacked within the battery. A three-dimensional (3D) electric model and a simplified equivalent resistance circuit (S-ERC) model of the AB-FB were proposed, both models were solved in steady-state regime. To validate the predictions of both models, a series of experiments were done in a commercial AB-FB conformed by four single cell units. The prediction error of the experimental polarization curves with the 3D electrical model was 2 %, while an error of 12 % was obtained with the S-ERC model. The 3D electric model simulations evidence the root source of shunt currents in the parallel electrolyte's feed/exit lines inside the AB-FB, which cause a 41 % of open circuit voltage (OCV) loss for 50 SCUs stacked within the battery, by reducing the cationic and anionic membrane thicknesses to 30 μm, the OCV loss for 50 SCUs stacked was 27 %. Extensive research work must be focused to reduce shunt currents on AB-FB, and related technologies, because they impact the battery electrical performance by reducing its gross power, voltage efficiency, open circuit voltage (OCV), and gross power density (GPD). • Charge and discharge polarization curves in steady-state regime • Voltage efficiency & power as function of the number of single cell unit in stack • Experimental current-voltage behavior of the AB-FB in stack for model validation • A novel and predictive three-dimensional (3D) electric model of the AB-FB • Root source of shunt currents in the electrolyte feed/exit lines within the AB-FB

Authors

Institutions

Publication Details

Journal
Journal of Energy Storage
Published
2025-05-05
DOI
https://doi.org/10.1016/j.est.2025.116898
Citations
2
Primary Topic
Advanced battery technologies research
Type
article
Field-Weighted Citation Impact
1.46

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental and modeling study of the current-potential behavior of an acid-base flow battery. Electrical performance determination as function of the number of single cell unit in stack

Eligio P. Rivero, Martín R. Cruz-Díaz, Gustavo Aparicio-Mauricio, Isidro Juvenal González Panzo
2 citations
Journal of Energy Storage
Advanced battery technologies research
1.46
article

Experimental and modeling study of the current-potential behavior of an acid-base flow battery. Electrical performance determination as function of the number of single cell unit in stack

Eligio P. Rivero, Martín R. Cruz-Díaz, Gustavo Aparicio-Mauricio, Isidro Juvenal González Panzo
article en
2 citations

Abstract

This work presents an experimental and modeling study of the current-potential behavior of an acid-base flow battery (AB-FB) by means of charge and discharge polarization curves in steady-state as function of the number of single cell units (SCUs) stacked within the battery. A three-dimensional (3D) electric model and a simplified equivalent resistance circuit (S-ERC) model of the AB-FB were proposed, both models were solved in steady-state regime. To validate the predictions of both models, a series of experiments were done in a commercial AB-FB conformed by four single cell units. The prediction error of the experimental polarization curves with the 3D electrical model was 2 %, while an error of 12 % was obtained with the S-ERC model. The 3D electric model simulations evidence the root source of shunt currents in the parallel electrolyte's feed/exit lines inside the AB-FB, which cause a 41 % of open circuit voltage (OCV) loss for 50 SCUs stacked within the battery, by reducing the cationic and anionic membrane thicknesses to 30 μm, the OCV loss for 50 SCUs stacked was 27 %. Extensive research work must be focused to reduce shunt currents on AB-FB, and related technologies, because they impact the battery electrical performance by reducing its gross power, voltage efficiency, open circuit voltage (OCV), and gross power density (GPD). • Charge and discharge polarization curves in steady-state regime • Voltage efficiency & power as function of the number of single cell unit in stack • Experimental current-voltage behavior of the AB-FB in stack for model validation • A novel and predictive three-dimensional (3D) electric model of the AB-FB • Root source of shunt currents in the electrolyte feed/exit lines within the AB-FB

Journal of Energy StorageVol. 124
Universidad de Cuautitlán Izcalli (MX), Universidad de Ecatepec (MX), Tecnológico de Estudios Superiores de Ecatepec
Consejo Nacional de Ciencia y Tecnología
Affordable and clean energy
Openalex Percentile: Top 18%
Advanced battery technologies research
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.