Enhanced Detection of High Impedance Faults in Smart Distribution Networks Using Differential Energy Indicators

The detection of high impedance faults (HIFs) plays a crucial role in modern active distribution systems to prevent risks like equipment failures, fire incidents, and disruptions in service, while maintaining a stable power supply. HIFs are challenging to detect due to their low-magnitude and fluctuating fault currents, often falling below the detection thresholds of conventional protection mechanisms. These undetected faults can result in significant safety hazards, economic losses, and compromised system reliability. This study presents an enhanced HIF detection method leveraging differential energy indicators derived from positive-sequence current components during fault events. The proposed approach improves fault detection accuracy and discriminates HIFs from nonfault transients, including load switching, capacitor switching, and nonlinear load effects. The method was validated through simulations on adapted IEEE-13 and IEEE-34 bus systems distribution networks with high distributed generation (DG) penetration. Results demonstrated faster response times (

Authors

Publication Details

Journal
PROtek Jurnal Ilmiah Teknik Elektro
Published
2025-05-05
DOI
https://doi.org/10.33387/protk.v12i2.9397
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced Detection of High Impedance Faults in Smart Distribution Networks Using Differential Energy Indicators

Hariani Ma’tang Pakka, M. Anas Masa, Andi Syarifuddin, Salmiah Salmiah et al.
PROtek Jurnal Ilmiah Teknik Elektro
Power Systems Fault Detection
article

Enhanced Detection of High Impedance Faults in Smart Distribution Networks Using Differential Energy Indicators

Hariani Ma’tang Pakka, M. Anas Masa, Andi Syarifuddin, Salmiah Salmiah, Syahrul Syahrul, Nurul Nurul
article en

Abstract

The detection of high impedance faults (HIFs) plays a crucial role in modern active distribution systems to prevent risks like equipment failures, fire incidents, and disruptions in service, while maintaining a stable power supply. HIFs are challenging to detect due to their low-magnitude and fluctuating fault currents, often falling below the detection thresholds of conventional protection mechanisms. These undetected faults can result in significant safety hazards, economic losses, and compromised system reliability. This study presents an enhanced HIF detection method leveraging differential energy indicators derived from positive-sequence current components during fault events. The proposed approach improves fault detection accuracy and discriminates HIFs from nonfault transients, including load switching, capacitor switching, and nonlinear load effects. The method was validated through simulations on adapted IEEE-13 and IEEE-34 bus systems distribution networks with high distributed generation (DG) penetration. Results demonstrated faster response times (

PROtek Jurnal Ilmiah Teknik ElektroVol. 12(2)
Openalex Percentile: Top 90%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Enhanced Detection of High Impedance Faults in Smart Distribution Networks Using Differential Energy Indicators — Hariani Ma’tang Pakka, M. Anas Masa, et al. · PROtek Jurnal Ilmiah Teknik Elektro (2025) | TGRS Research Map | TGRS