Simulation Study on the Electric Field of Three-Phase Three-Post Insulators Under Typical Defects

In three-phase three-post insulators, air gaps and crack defects are important sources of partial discharge and surface flashover. Using finite element analysis software, this study created a three-dimensional simulation model to investigate the effect of these defects on electric field distribution. The effects of crack defects and air gaps of different sizes and locations on the electric field distribution were then methodically investigated. According to the results, the most significant electric field distortion is caused by air gap defects close to the phase A conductor, and the distortion is exacerbated by shorter air gap lengths. Air gap length has much less effect on the electric field in the phase B conductor. There is no obvious change in electric field strength with the radius of air gap defects (0.1–2 mm). The electric field strength is negatively correlated with crack height; greater height reduces distortion, while crack width and depth are positively correlated with the surrounding field strength; greater dimensions increase distortion.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-05-03
DOI
https://doi.org/10.3390/en18092344
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation Study on the Electric Field of Three-Phase Three-Post Insulators Under Typical Defects

Hongze Li, Xiaolong Li, Lixiang Lv, Zhuoran Yang et al.
Energies
High voltage insulation and dielectric phenomena
article

Simulation Study on the Electric Field of Three-Phase Three-Post Insulators Under Typical Defects

Hongze Li, Xiaolong Li, Lixiang Lv, Zhuoran Yang, Yue Wang, Hao Wang, Jian Liu
article en

Abstract

In three-phase three-post insulators, air gaps and crack defects are important sources of partial discharge and surface flashover. Using finite element analysis software, this study created a three-dimensional simulation model to investigate the effect of these defects on electric field distribution. The effects of crack defects and air gaps of different sizes and locations on the electric field distribution were then methodically investigated. According to the results, the most significant electric field distortion is caused by air gap defects close to the phase A conductor, and the distortion is exacerbated by shorter air gap lengths. Air gap length has much less effect on the electric field in the phase B conductor. There is no obvious change in electric field strength with the radius of air gap defects (0.1–2 mm). The electric field strength is negatively correlated with crack height; greater height reduces distortion, while crack width and depth are positively correlated with the surrounding field strength; greater dimensions increase distortion.

EnergiesVol. 18(9)
Shenyang University of Technology (CN)
Science and Technology Project of State Grid, State Grid Jiangsu Electric Power
Openalex Percentile: Top 94%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Simulation Study on the Electric Field of Three-Phase Three-Post Insulators Under Typical Defects — Hongze Li, Xiaolong Li, et al. · Energies (2025) | TGRS Research Map | TGRS