Quantification of smokeless powder (SLP) additives on hands after direct handling of bulk samples via a filter-and-shoot method

Smokeless powders (SLPs) are easily available energetic materials that are often used in the construction of improvised explosive devices. Following a bombing incident, hand swabs are routinely collected from persons of interest (POIs) to assess potential SLP handling. However, the evidential significance of analytical findings remains difficult to assign due to the lack of systematic data on residue transfer. This study aimed to address this gap by determining the quantities transferred to hands (q<sub>T</sub>) of three common SLP additives - diphenylamine (DPA), dibutyl phthalate (DBP), and ethyl centralite (EC) - following direct handling of bulk samples, with the specific goal of enabling the estimation of expected q<sub>T</sub> ranges on a POI's hands under the hypothesis that they had handled SLP. A streamlined filter-and-shoot method was developed for residue collection and analysis, allowing direct chromatographic analysis without preconcentration steps. The results showed that q<sub>T</sub> values typically ranged from the high nanogram to low microgram level, with DBP exhibiting the highest values and EC the lowest, mirroring their relative concentrations in the SLP formulations. The total mass of SLP handled (M<sub>SLP</sub>) and the handler variability (H<sub>ID</sub>) were identified as significant factors influencing q<sub>T</sub>, whereas the type of SLP (T<sub>SLP</sub>) had a much weaker effect. Notably, a strong linear dependence between q<sub>T</sub> and M<sub>SLP</sub> was observed for all the three compounds. Based on these findings, regression models were developed to estimate expected q<sub>T</sub> ranges (including means and standard deviations) at different M<sub>SLP</sub> values, providing a practical tool to refine interpretation where information on the amount of SLP handled is available. By establishing empirical data on SLP residue transfer, this study fills a critical knowledge gap in the literature, enhancing the ability to assess the significance of forensic findings and ultimately contributing to more robust interpretations in cases involving suspected SLP handling.

Authors

Institutions

Publication Details

Journal
Science & Justice
Published
2025-05-04
DOI
https://doi.org/10.1016/j.scijus.2025.101262
Primary Topic
Chemical Safety and Risk Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantification of smokeless powder (SLP) additives on hands after direct handling of bulk samples via a filter-and-shoot method

Matteo D. Gallidabino, C. D. Kelly, Nathalie Mai, J. Liechti et al.
2 links
Science & Justice
Chemical Safety and Risk Management
article

Quantification of smokeless powder (SLP) additives on hands after direct handling of bulk samples via a filter-and-shoot method

Matteo D. Gallidabino, C. D. Kelly, Nathalie Mai, J. Liechti, Gavin Lambert, Troy Standley, Carissa M. Putruele, Zara Redshaw, Nadia T Stephaniuk
article en

Abstract

Smokeless powders (SLPs) are easily available energetic materials that are often used in the construction of improvised explosive devices. Following a bombing incident, hand swabs are routinely collected from persons of interest (POIs) to assess potential SLP handling. However, the evidential significance of analytical findings remains difficult to assign due to the lack of systematic data on residue transfer. This study aimed to address this gap by determining the quantities transferred to hands (q<sub>T</sub>) of three common SLP additives - diphenylamine (DPA), dibutyl phthalate (DBP), and ethyl centralite (EC) - following direct handling of bulk samples, with the specific goal of enabling the estimation of expected q<sub>T</sub> ranges on a POI's hands under the hypothesis that they had handled SLP. A streamlined filter-and-shoot method was developed for residue collection and analysis, allowing direct chromatographic analysis without preconcentration steps. The results showed that q<sub>T</sub> values typically ranged from the high nanogram to low microgram level, with DBP exhibiting the highest values and EC the lowest, mirroring their relative concentrations in the SLP formulations. The total mass of SLP handled (M<sub>SLP</sub>) and the handler variability (H<sub>ID</sub>) were identified as significant factors influencing q<sub>T</sub>, whereas the type of SLP (T<sub>SLP</sub>) had a much weaker effect. Notably, a strong linear dependence between q<sub>T</sub> and M<sub>SLP</sub> was observed for all the three compounds. Based on these findings, regression models were developed to estimate expected q<sub>T</sub> ranges (including means and standard deviations) at different M<sub>SLP</sub> values, providing a practical tool to refine interpretation where information on the amount of SLP handled is available. By establishing empirical data on SLP residue transfer, this study fills a critical knowledge gap in the literature, enhancing the ability to assess the significance of forensic findings and ultimately contributing to more robust interpretations in cases involving suspected SLP handling.

Science & JusticeVol. 65(4)
King's College London (GB), Defence Academy of the United Kingdom (GB)
King’s College London, Royal Society of Chemistry
Zero hunger
Openalex Percentile: Top 89%
Chemical Safety and Risk Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.