In Vitro Comparison of the Mechanical and Optical Characteristics of the Storz Flex-XC1 Singleuse Ureteroscope and the Storz Flex-XC Reusable Flexible Ureteroscope

Objective: This study compared the mechanical and optical characteristics of the Storz Flex-XC1 single-use ureteroscope and the Storz Flex-XC reusable flexible ureteroscope. The mechanical parameters comprised the upward/downward deflection, loop diameter, and irrigation flow rate. The optical parameters were image resolution and color representation. Materials and Methods: We conducted an in vitro evaluation of two Karl Storz flexible ureteroscopes. Specifically, we examined the Storz Flex-XC1 single-use and Storz Flex-XC reusable scopes for upward/downward deflection angles, loop diameter, irrigation flow rates, image resolution, and color representation. The Storz Professional Image Enhancement System was also applied. Results: The Storz Flex-XC reusable ureteroscope achieved greater upward/downward deflection angles than did the Storz Flex-XC1 single-use ureteroscope when a 200 μm laser or a 1.9 Fr tipless basket was used, with mean differences of 1.9°‒2.2° and 2.3°‒5.6°, respectively. No clinically significant difference in loop diameter was found. The Storz Flex reusable scope achieved a higher irrigation flow rate with an empty working channel (mean difference of 2.25 ml/min). Both scopes demonstrated identical image resolutions in air and in a normal saline solution, but the Storz Flex single-use device showed superior color representation. Conclusion: The Storz Flex-XC reusable flexible ureteroscope displayed slight advantages in terms of the deflection angle and irrigation flow rate. The Storz Flex-XC1 single-use flexible ureteroscope offered improved color representation and marginally better resolution in saline.

Authors

Institutions

Publication Details

Journal
Siriraj Medical Journal/San Sirirat
Published
2025-05-01
DOI
https://doi.org/10.33192/smj.v77i5.272982
Primary Topic
Kidney Stones and Urolithiasis Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In Vitro Comparison of the Mechanical and Optical Characteristics of the Storz Flex-XC1 Singleuse Ureteroscope and the Storz Flex-XC Reusable Flexible Ureteroscope

Tawatchai Taweemonkongsap, Kittipong Phinthusophon, Sittiporn Srinualnad, Thitipat Hansomwong et al.
Siriraj Medical Journal/San Sirirat
Kidney Stones and Urolithiasis Treatments
article

In Vitro Comparison of the Mechanical and Optical Characteristics of the Storz Flex-XC1 Singleuse Ureteroscope and the Storz Flex-XC Reusable Flexible Ureteroscope

Tawatchai Taweemonkongsap, Kittipong Phinthusophon, Sittiporn Srinualnad, Thitipat Hansomwong, Ekkarin Chotikawanich, Patkawat Ramart, Siros Jitpraphai, Kantima Jongjitaree, Varat Woranisarakul, Thawatchai Mankongsrisuk, Chittapanya Leelathanyakit
article en

Abstract

Objective: This study compared the mechanical and optical characteristics of the Storz Flex-XC1 single-use ureteroscope and the Storz Flex-XC reusable flexible ureteroscope. The mechanical parameters comprised the upward/downward deflection, loop diameter, and irrigation flow rate. The optical parameters were image resolution and color representation. Materials and Methods: We conducted an in vitro evaluation of two Karl Storz flexible ureteroscopes. Specifically, we examined the Storz Flex-XC1 single-use and Storz Flex-XC reusable scopes for upward/downward deflection angles, loop diameter, irrigation flow rates, image resolution, and color representation. The Storz Professional Image Enhancement System was also applied. Results: The Storz Flex-XC reusable ureteroscope achieved greater upward/downward deflection angles than did the Storz Flex-XC1 single-use ureteroscope when a 200 μm laser or a 1.9 Fr tipless basket was used, with mean differences of 1.9°‒2.2° and 2.3°‒5.6°, respectively. No clinically significant difference in loop diameter was found. The Storz Flex reusable scope achieved a higher irrigation flow rate with an empty working channel (mean difference of 2.25 ml/min). Both scopes demonstrated identical image resolutions in air and in a normal saline solution, but the Storz Flex single-use device showed superior color representation. Conclusion: The Storz Flex-XC reusable flexible ureteroscope displayed slight advantages in terms of the deflection angle and irrigation flow rate. The Storz Flex-XC1 single-use flexible ureteroscope offered improved color representation and marginally better resolution in saline.

Siriraj Medical Journal/San SiriratVol. 77(5)
Siriraj Hospital (TH), Mahidol University (TH)
Faculty of Medicine Siriraj Hospital, Mahidol University
Openalex Percentile: Top 85%
Kidney Stones and Urolithiasis Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.